Skip to content

Occlutech Delivery Set III 98DS014Recalls & reported problems

Oscor Inc. · OCCLUTECH DELIVERY SET III, 14F 79CM 45° · Class 2

All models of Occlutech Delivery Set III (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00885672010362), received between Oct 23, 2023 and Sep 21, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Air/Gas in Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Air/Gas in Device1
  • Difficult to Advance1
  • Loose or Intermittent Connection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 21, 2026Difficult to Advance

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50843910 ↗
  • MalfunctionJul 15, 2025Loose or Intermittent Connection; Loose or Intermittent Connection

    DURING AN IMPLANTATION PROCEDURE, THE PHYSICIAN WANTED TO INSERT THE ODSIII SHEATH 14F INTO THE FEMORAL VEIN AND DISCOVERED THAT THE CONNECTION BETWEEN THE VALVE AND THE SHEATH WAS NOT TIGHT. THE PHYSICIAN WAS ABLE TO PULL THE VALVE OFF THE SHEATH EASILY. IT WAS THEN SWITCHED TO A NEW ODSIII SHEATH 14F AND THE IMPLANTATION WAS SUCCESSFULLY COMPLETED WITHOUT ANY FURTHER INCIDENTS. THE PATIENT LEFT THE CATH LAB WITHOUT ANY COMPLAINTS AND WAS IN GOOD CONDITION. IT WAS ALSO REPORTED THE VALVE WAS NOT FIRMLY CONNECTED TO THE SHEATH. THERE WAS NO GAP AT VALVE WHEN THE DILATOR WAS INSERTED OR ANY OTHER ANCILLARY DEVICE. THE VALVE HAS DETACHED ITSELF FROM THE SHEATH. NO PICTURES OR VIDEO AVAILABLE AND NO DELAY IN THE PROCEDURE. NO ADDITIONAL MEDICAL OR SURGICAL INTERVENTION. NO ANATOMICAL ABNORMALITIES PATIENT WAS A YOUNG SLIM MAN. DEVICE WILL BE RETURNED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22510237 ↗
  • MalfunctionOct 23, 2023Air/Gas in Device; Air/Gas in Device

    THE CUSTOMER REPORTED THE EVENT OCCURRED DURING PATIENT CONTACT. THE COMPLAINT AFFECTS THE LOADER, WHILE FLUSHING WITH THE DEVICE IN IT, THERE WERE AIR BUBBLES ENTERING THE LOADER FROM THE HEMOSTATIC VALVE. AFTER FLUSHING THE DEVICE, AIR GOT IN THE LOADER AGAIN WHILE BRINGING THE LOADER TO THE SHEATH. AS SOON AS THE PUSHER SLIGHTLY MOVED, THERE WAS AIR ENTERING THE LOADER AGAIN FROM THE HEMOSTATIC VALVE. THE PHYSICIAN HOLDS THE PUSHER AND LOADER COMPLETELY STILL SO THAT IT WORKED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17985188 ↗

Other INTRODUCER, CATHETER devices

All INTRODUCER, CATHETER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page