Intuitive Surgical, Inc. · TUBE SET WITH SMOKE EVACUATION · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00886874120699), received between Mar 26, 2026 and May 11, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Gas/Air Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Gas/Air Leak1
  • Output Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 11, 2026Output Problem

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, A NOTIFICATION APPEARED STATING THAT THE TOWER TOUCHSCREEN WAS NOT FUNCTIONING. THE FILTER FUNCTION ALSO DID NOT WORK WHEN USING ENERGY, MAKING IT DIFFICULT TO MAINTAIN VISIBILITY. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE ISSUE WAS RESOLVED WITH BACKUP INSUFFLATOR SMOKE EVACUATION. THE PROCEDURE WAS COMPLETED AS PLANNED. THEY DID NOT USE AN EXTERNAL SUCTION DEVICE INSTEAD OF THE INSUFFLATOR SMOKE EVACUATION. THE ISSUE OCCURRED WHEN THE SMOKE EVACUATION FUNCTION WAS TURNED ON AFTER DOCKING. THE TOUCHSCREEN WAS NOT FUNCTIONING. THE ISSUE HAS NOT RECURRED SINCE THE REPORTED EVENT. THE INSUFFLATION TUBESET WAS INSPECTED WITH NO DAMAGE OBSERVED. THERE WAS NO PATIENT INJURY OR HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25143189 ↗
  • MalfunctionMar 26, 2026Gas/Air Leak

    IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED SURGICAL PROCEDURE, THE ABDOMINAL PRESSURE SUDDENLY DROPPED TO ZERO DURING SURGERY AND COULD NOT BE INCREASED. AFTER THAT THE PRESSURE WAS SET TO THE SET PRESSURE AND KEPT IT. THE TECHNICAL SUPPORT ENGINEER (TSE) ADVISED CHECKING THE HOSES, CONNECTORS AND SETTINGS. THEN, THEY FOUND THE ISSUE OCCURRED WHEN A SURGEON WAS USING A VACUUM MACHINE. THE TSE EXPLAINED THAT WAS THE MOST LIKELY CAUSE, SO ADVISED ADJUSTING THE FLOW RATE OR SET PRESSURE HIGHER. AFTER THE FIRST CALL, THE ISSUE STILL PERSISTED, SO THEY REPLACED THE TUBE SET AND THEN THE ISSUE WAS COMPLETELY RESOLVED. THE TSE ADVISED TO RETURN THE ORIGINAL ONE. THE PROCEDURE WAS COMPLETED AS PLANNED WITH NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24706784 ↗

Other Insufflator, laparoscopic devices

All Insufflator, laparoscopic devices →