HIGH FLOW INSUFFLATION UNIT UHI-3 (UDI 04953170140297)Recalls & reported problems

Olympus Medical Systems Corp. · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This Olympus high flow insufflation unit supplies gas during laparoscopic surgery. Many of the 162 reports describe gas leaks, pressure problems, and units that fail to power up, often found during device evaluation. The reports include no deaths and 2 injuries. There is 1 open recall, started in January 2026, about a software issue that may lead to excess pressure.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
162
Deaths reported
0
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 162 adverse event reports that list this exact device (DI 04953170140297), received between Sep 18, 2018 and Apr 21, 2026 — classified as 2 injuries, 160 malfunctions.

The most frequently reported specific device problem is “Gas/Air Leak” (20 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 5 reportsDec 2023: 4 reportsJan 2024: 6 reportsFeb 2024: 5 reportsMar 2024: 4 reportsApr 2024: 1 reportsMay 2024: 3 reportsJun 2024: 2 reportsJul 2024: 7 reportsAug 2024: 1 reportsSep 2024: 3 reportsOct 2024: 5 reportsNov 2024: 2 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 3 reportsApr 2025: 1 reportsMay 2025: 3 reportsJun 2025: 0 reportsJul 2025: 3 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 3 reportsFeb 2026: 2 reportsMar 2026: 3 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520267
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jan 16, 2026Open, Classified

    Issue with software algorithm which may lead to overpressure events.

    Z-1354-2026 · Root cause: Software design · FDA record ↗

Most reported problems

Device problems

  • Gas/Air Leak20
  • Pressure Problem16
  • Failure to Power Up15
  • Display or Visual Feedback Problem9
  • Gas Output Problem8
  • Improper Flow or Infusion8
  • Electrical /Electronic Property Problem7
  • Increase in Pressure7

Patient problems

  • No Clinical Signs, Symptoms or Conditions138
  • No Consequences Or Impact To Patient19
  • No Known Impact Or Consequence To Patient2
  • Injury1
  • Respiratory Insufficiency1
  • Unspecified Respiratory Problem1

Recent adverse event reports

The 25 most recent of 162 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 21, 2026Gas Output Problem; Material Deformation; No Visual Prompts/Feedback

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HIGH FLOW INSUFFLATION UNIT HAD NO VALUE OF PRESSURE, THE FLOW RATE AND VOLUME WERE SHOWING ON THE FRONT PANEL ALTHOUGH NO GAS WAS BEING SUPPLIED DUE TO A FAULTY MAIN BOARD. ADDITIONALLY, THE TUBING WAS DIRTY AND YELLOWISH DUE TO A FAULTY TUBE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24940417 ↗
  • MalfunctionApr 20, 2026Gas/Air Leak; Mechanical Jam

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HIGH FLOW INSUFFLATION UNIT HAD A GAS LEAKAGE AND TUBE STUCK IN FIRST REGULATOR UNIT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24927488 ↗
  • MalfunctionMar 31, 2026Loose or Intermittent Connection

    DURING THE DEVICE EVALUATION, IT WAS FOUND THAT THE ELECTROPNEUMATIC PROPORTIONAL VALVE UNIT WAS LOOSE ON THE HIGH FLOW INSUFFLATION UNIT. NO PATIENTS WERE INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24744443 ↗
  • MalfunctionMar 3, 2026Gas/Air Leak; Material Integrity Problem

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HIGH FLOW INSUFFLATION UNIT EXHIBITED GAS LEAKAGE FROM THE PRIMARY PIPING AND A LOOSE CONNECTOR. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24497437 ↗
  • MalfunctionMar 3, 2026Scratched Material

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HIGH FLOW INSUFFLATION UNIT EXHIBITED A SCRATCH ON THE PINCH VALVE AND A MALFUNCTIONING RELIEF MODE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24494475 ↗
  • MalfunctionFeb 20, 2026No Device Output; Material Deformation

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HIGH FLOW INSUFFLATION UNIT'S LEDS WERE FLICKERING BECAUSE THE FRONT PANEL IS DEPRESSED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24402741 ↗
  • MalfunctionFeb 5, 2026Gas/Air Leak

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24268281 ↗
  • MalfunctionJan 23, 2026Infusion or Flow Problem

    IT WAS REPORTED THE HIGH FLOW INSUFFLATION UNIT'S INSUFFLATION WAS NOT WORKING. THE ISSUE OCCURRED DURING SET UP OR INSPECTION FOR USE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24169025 ↗
  • MalfunctionJan 13, 2026Break; Display or Visual Feedback Problem; Insufficient Flow or Under Infusion; Gas/Air Leak

    NO ADDITIONAL INFORMATION PROVIDED BY THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24060720 ↗
  • MalfunctionJan 5, 2026Gas Output Problem

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23959192 ↗
  • MalfunctionDec 30, 2025Pressure Problem; Pressure Problem

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23924866 ↗
  • MalfunctionDec 10, 2025Noise, Audible; Noise, Audible

    IT WAS REPORTED THAT DURING DEVICE SERVICE AND MAINTENANCE, THE HIGH FLOW INSUFFLATION WAS NOT WORKING, WITH A LEAKAGE SOUND COMING FROM THE MACHINE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23767509 ↗
  • MalfunctionOct 15, 2025Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED THE SUBJECT DEVICE EXHIBITED LEAKAGE FROM INSUFFLATOR. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23304747 ↗
  • MalfunctionSep 16, 2025Break; Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE SUBJECT DEVICE EXHIBITED MANIFOLD DAMPER WAS DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23066904 ↗
  • MalfunctionJul 22, 2025Gas/Air Leak; Gas/Air Leak

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22565893 ↗
  • MalfunctionJul 22, 2025Circuit Failure; Increase in Pressure; Circuit Failure; Increase in Pressure

    IT WAS REPORTED THE INSUFFLATION UNIT PRESENTED A PRESSURE ALARM AND THE MAIN BOARD WAS NO GOOD. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22563660 ↗
  • MalfunctionJul 3, 2025Pressure Problem; Pressure Problem

    IT WAS REPORTED THAT THE SUBJECTED DEVICE PRESSURE DIFFERENCE IS TOO LARGE. THE EVENT OCCURRED DURING SET UP / INSPECTION FOR USE (BEFORE PATIENT IN ROOM) THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22399459 ↗
  • MalfunctionMay 19, 2025Increase in Pressure; Increase in Pressure

    IT WAS REPORTED THAT THE SUBJECT DEVICE PRESENTED A PRESSURE ALARM. THE ISSUE WAS FOUND DURING SET UP / INSPECTION FOR USE (DURING SET UP IN ROOM / BEFORE PATIENT IN ROOM). THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22045243 ↗
  • MalfunctionMay 2, 2025Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED THE SUBJECT PRODUCT PRODUCED AN AIR LEAK. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21952950 ↗
  • MalfunctionMay 1, 2025Failure to Power Up; Failure to Power Up

    NO ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21943498 ↗
  • MalfunctionApr 25, 2025Insufficient Flow or Under Infusion; Insufficient Flow or Under Infusion

    IT WAS REPORTED THE SUBJECT DEVICE EXHIBITED INSUFFLATION IS TOO SLOW TO CONTINUE THE PROCEDURE. THE ISSUE OCCURRED DURING SERVICE / MAINTENANCE (NOT IN A CLINICAL SETTING). THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21909734 ↗
  • MalfunctionMar 27, 2025Failure to Power Up; Failure to Power Up

    IT WAS REPORTED THAT THE SUBJECT DEVICE START BUTTON WAS OUT OF ORDER. THE ISSUE OCCURRED DURING SET UP / INSPECTION FOR USE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21713536 ↗
  • MalfunctionMar 19, 2025No Display/Image; No Display/Image

    IT WAS REPORTED THAT THE SUBJECT DEVICE HAD A POOR TOUCH PANEL. THIS ISSUE OCCURRED DURING SETUP/INSPECTION FOR USE (DURING SETUP IN THE ROOM/BEFORE THE PATIENT WAS IN THE ROOM). THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21647133 ↗
  • MalfunctionMar 11, 2025Device Alarm System; Activation Problem; Device Alarm System; Activation Problem

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE SUBJECT DEVICE EXHIBITED OCCASIONAL STARTUP ALARM WITH BLACK SCREEN DUE TO FAULTY MAIN BOARD. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21569925 ↗
  • MalfunctionDec 13, 2024Pressure Problem; Pressure Problem

    NO OTHER ADDITIONAL INFORMATION FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20925057 ↗

Other INSUFFLATOR, LAPAROSCOPIC devices