VuePoint 8980000PRecalls & reported problems
Nuvasive, Inc. · VuePoint II Keel Plate + Set Screws · Class 2 · Implant
All models of VuePoint (26)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887517954398), received between Dec 13, 2022 and Dec 13, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fracture1
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 13, 2022Fracture; Material Deformation; Fracture; Material Deformation
IN (B)(6) 2022 A PATIENT UNDERWENT A LAMINECTOMY AND FUSION PROCEDURE AT C3/4 DUE TO CHIN ON CHEST AND EXTREME KYPHOSIS FOLLOWING CERVICAL LAMINECTOMY AND SPONDYLODESIS AT C3/4. APPROXIMATELY SEVEN MONTHS POST OP THE PATIENT EXPERIENCED "CRACKLING" NOISES FROM THEIR NECK AND SUBSEQUENT IMAGING FOUND THE OCCIPITAL PLATE HAD FRACTURED AT THE TULIP ON ONE SIDE OF THE PLATE AND THERE WAS NOTED LUXATION OF THE ROD CONNECTED TO THE TULIP ON THE OTHER SIDE OF THE PLATE. ON (B)(6) 2022 AN ANTERIOR CORPECTOMY WAS PERFORMED FROM C5-7 WITH POSTERIOR FIXATION INSTALLATION FROM OCCIPUT TO T4 TO ADDRESS EXTREME CERVICAL KYPHOSIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15974094 ↗
Other Orthosis, cervical pedicle screw spinal fixation devices
- INFINITY™ Occipitocervical Upper Thoracic System 3604026Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation2 recalls1 report
- CONNECTOR 79-2003Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 360PT4022Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- CONNECTOR 79-2002Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604532Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604024Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- OASYS 48551000Stryker Corporation · Orthosis, cervical pedicle screw spinal fixation45 reports
- YUKON OCT Spinal System 7601-05030VB Spine LLC · Orthosis, cervical pedicle screw spinal fixation15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page