ReLine D10000482Recalls & reported problems
Nuvasive, Inc. · RELINE MAS Reducer, Pile Driver Dism · Class 1
All models of ReLine (129)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887517995452), received between Jan 26, 2024 and Jan 26, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 26, 2024Fracture; Fracture
IT WAS REPORTED THAT DURING A POSTERIOR FIXATION PROCEDURE WHILE FINAL TIGHTENING A LOCK SCREW AT RIGHT L4, THE DRIVER TIP FRACTURED OFF AND LODGED WITHIN THE LOCK SCREW. THE FRACTURE REPORTEDLY OCCURRED AFTER THE ASSOCIATED TORQUE LIMITING HANDLE DID NOT RELEASE THE TORQUE AS EXPECTED, RESULTING IN THE SURGEON USING BOTH HANDS ON THE TORQUE HANDLE TO TIGHTEN THE LOCK SCREW AND LEADING TO THE SUBSEQUENT TIP FRACTURE. AFTER AN UNSUCCESSFUL ATTEMPT TO REMOVE THE FRACTURED TIP WITH A MAGNET, THE SURGEON DECIDED TO LEAVE THE TIP IN-SITU, LODGED WITHIN THE LOCK SCREW, AND PROCEED WITH THE PROCEDURE. THERE HAS BEEN NO REPORT OF ADVERSE PATIENT IMPACT AS A RESULT OF THIS EVENT.
Patient problems: Foreign Body In Patient
MAUDE report 18592058 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page