ICU Medical B9449Recalls & reported problems
Icu Medical, Inc. · 99" (251 cm) 20 Drop Y-Type Blood Set w/200 Micron Filter, Hand Pump, 2 Clave®, Rotating Luer · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00887709013902), received between Sep 4, 2024 and Oct 15, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Air/Gas in Device” (1 report).
54 other recalls cover devices cleared under the same FDA submission (K983559); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Air/Gas in Device1
- Insufficient Flow or Under Infusion1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 15, 2025Air/Gas in Device; Air/Gas in Device
THE EVENT INVOLVED A 99" (251 CM) 20 DROP Y-TYPE BLOOD SET W/200 MICRON FILTER, HAND PUMP, 2 CLAVE®, ROTATING LUER WHERE IT WAS REPORTED THAT THE LITTLE DRIPPER GETS AIR IN BLOOD SET, HARD TO PRIME AND INFUSE BLOOD PRODUCTS. THE MEDICATION BEING USED WITH THIS IS ALBUMIN. THERE WAS PATIENT INVOLVEMENT, NO PATIENT HARM OR ADVERSE EVENTS. THERE WAS DELAY IN THERAPY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23292059 ↗MalfunctionSep 4, 2024Insufficient Flow or Under Infusion; Insufficient Flow or Under Infusion
THE EVENT OCCURRED ON AN UNSPECIFIED DATE AND INVOLVED A 99" (251 CM) 20 DROP Y-TYPE BLOOD SET W/200 MICRON FILTER, HAND PUMP, 2 CLAVE®, ROTATING LUER WHERE IT WAS REPORTED THE SPIKE ON THE ICU MEDICAL TUBING IS CLOTTING OFF. WHEN THIS HAPPENS, IT CAUSES A VACUUM IN THE TUBING THAT DOESN¿T ALLOW THE BLOOD PRODUCTS TO MOVE FORWARD TO THE PATIENT; THE BULB FOR SQUEEZING COLLAPSES. IT WAS REPORTED THE EVENT HINDERED AND SLOWED THE TRANSFUSION PROCESS, AND A WASTAGE OF BLOOD PRODUCTS DUE TO HAVING TO SWITCH TO FRESH BLOOD Y TYPED TUBING. THE EVENT OCCURRED WHILE ACTIVELY TRYING TO TRANSFUSE PACKED RED BLOOD CELLS TO PATIENTS IN THE OPERATING ROOM. THERE WAS PATIENT INVOLVEMENT AND NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20135280 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K983559. One submission often covers many models, so check the product and lot details in each record.
- Z-0711-2021 · Aug 31, 2020 · Open, Classified26 IN(66 cm) APPX 3.4ml, 10 DROP BLOOD SET, 170 MICRON FILTER, Spiros, REF: Z2795
- Z-2606-2018 · Jul 31, 2017 · Terminated119" Blood Set w/200 Micron Filter, Clave, Rotating Luer, Sterile The blood tubing accessory with CLAVE Connector is a single use, sterile, non-pyrogenic device intended for use a
- Z-2638-2018 · Jul 31, 2017 · Terminated162" Y-Type Blood Set w/170 Micron Filter, Bulb Hand Pump, 3 Pre-Pierced Ports, 4 Gang 4-Way Stopcocks w/Baseplate, 3 Remv Ext, Rotating Luers, Sterile The blood tubing accessory
- Z-2612-2018 · Jul 31, 2017 · Terminated218 cm (86") Appx 16.4 ml, 20 Drop Blood Set w/200 Micron Filter, 2 MicroClave, Check Valve, Y-Connector, Rotating Luer, Sterile The blood tubing accessory with CLAVE Connector is
- Z-2648-2018 · Jul 31, 2017 · Terminated143" (363 cm) 20 Drop Y-Type Blood Set w/200 Micron Filter, Hand Pump, 2 Clave, Drop-In Ext w/3 Gang 4 Way Stopcocks, MicroClave, Luer Lock, Sterile The blood tubing accessory wit
- Z-2634-2018 · Jul 31, 2017 · Terminated164" (417 cm) 20 Drop Y-Type Blood Admin Set w/200 Micron Filter, Hand Pump, Remv 4 Gang 4-Way Stopcocks w/Baseplate, 4 MicroClave Clear, Rotating Luer, 1 Ext, Sterile The blood t
- Z-2615-2018 · Jul 31, 2017 · Terminated112" Y-Type Blood Set w/170 Micron Filter, Hand Pump, Pre-Slit Port, Rotating Luer, Sterile The blood tubing accessory with CLAVE Connector is a single use, sterile, non-pyrogenic
- Z-2629-2018 · Jul 31, 2017 · Terminated132" (335 cm) Y-Type Blood Set w/170 Micron Filter, Hand Pump, Clave, 4-Way Stopcock, Rotating Luer, 1 Ext, Sterile The blood tubing accessory with CLAVE Connector is a single use
- Z-2611-2018 · Jul 31, 2017 · Terminated32" (81 cm) Appx 4.4 mL Blood Set w/20 Drop 200 Micron Filter, Rotating Luer, Sterile The blood tubing accessory with CLAVE Connector is a single use, sterile, non-pyrogenic devic
- Z-2657-2018 · Jul 31, 2017 · Terminated116" (295 cm) Y-Type Blood Set w/170 Micron Filter, Hand Pump, 3 MicroClave, 2 Ext, Rotating Luer, Sterile The blood tubing accessory with CLAVE Connector is a single use, sterile
- Z-2633-2018 · Jul 31, 2017 · Terminated125" (318 cm) Bifuse Blood Set w/170 Micron Filter, Hand Pump, 4 MicroClave Clear, Rotating Luer, 1 Ext, Sterile The blood tubing accessory with CLAVE Connector is a single use, s
- Z-2658-2018 · Jul 31, 2017 · Terminated120" (305 cm) 10 Drop Primary Set w/2 MicroClave, Hand Pump, Remv 2 Gang 4-Way Stopcock, Y-Connector, Rotating Luer, 1 Ext, Sterile The blood tubing accessory with CLAVE Connector
- Z-2646-2018 · Jul 31, 2017 · Terminated132" (335 cm) Y-Type Admin Set w/170 Micron Blood Filter, Pump, 2 Clave, Remv 2 Gang 4-Way Stopcocks, Luer Lock, 2 Ext, Sterile The blood tubing accessory with CLAVE Connector is a
- Z-2642-2018 · Jul 31, 2017 · Terminated100" (254 cm) 20 Drop Y-Type Blood Admin Set w/200 Micron Filter, Hand Pump, 2 Clave, Rotating Luer w/Filter Cap, Sterile The blood tubing accessory with CLAVE Connector is a sing
- Z-2645-2018 · Jul 31, 2017 · Terminated98" (249 cm) Y-Type Admin Set w/170 Micron Blood Filter, Pump, Clave, 2 Gang 4-Way Stopcocks, Luer Lock, 1 Ext, Sterile The blood tubing accessory with CLAVE Connector is a single
…and 39 more.
Other SET, TUBING, BLOOD, WITH AND WITHOUT ANTI-REGURGITATION VALVE devices
- Hemodialysis Bloodlines SL-2010M2096B. Braun Medical Inc. · Set, tubing, blood, with and without anti-regurgitation valve3 recalls3 deaths1,000 reports
- Hemodialysis Bloodlines SL-2010M2096AB. Braun Medical Inc. · Set, tubing, blood, with and without anti-regurgitation valve2 recalls1 death483 reports
- Hemodialysis Bloodlines SL-2000M2095DAB. Braun Medical Inc. · Set, tubing, blood, with and without anti-regurgitation valve2 recalls1 death214 reports
- CombiSet 03-2722-9Fresenius Medical Care Holdings, Inc. · SET, TUBING, BLOOD, WITH AND WITHOUT ANTI-REGURGITATION VALVE8 deaths311 reports
- Hemodialysis Bloodlines SL-2000M2095B. Braun Medical Inc. · Set, tubing, blood, with and without anti-regurgitation valve1 recall219 reports
- CombiSet 03-2522-1Fresenius Medical Care Holdings, Inc. · Set, Tubing, Blood, With And Without Anti-Regurgitation Valve1 recall214 reports
- Cartridge Blood Set 101025Gambro Renal Products, S.A. de C.V. · SET, TUBING, BLOOD, WITH AND WITHOUT ANTI-REGURGITATION VALVE3 recalls80 reports
- Hemodialysis Bloodlines SL-2000M2095DB. Braun Medical Inc. · Set, tubing, blood, with and without anti-regurgitation valve1 recall158 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page