AFFIXUS®HIP FRACTURE NAIL - LEFT 8146-11-340Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of AFFIXUSHIP FRACTURE NAIL - LEFT (27)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00887868039805), received between Oct 30, 2025 and Oct 30, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
1 FDA recall record name this device's identifier.
249 other recalls cover devices cleared under the same FDA submission (K100238); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Aug 7, 2017Class IITerminated
During the rework process for the April 17, 2017, field action, it was detected that the set screw and sleeve assembly which are designed to have an interference fit, were no longer in the installed location. This could prevent the product assembly with the mating screw and targeting jig.
Z-0434-2018 · Root cause: Process change control · Recall details · FDA record ↗
Most reported problems
Device problems
- Fracture1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 30, 2025Fracture; Fracture
IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL LEFT FEMUR FRACTURE SURGERY. SUBSEQUENTLY, THE PATIENT WAS REVISED ON APPROXIMATELY 1 MONTH POST-IMPLANTATION DUE TO THE AFFIXUS NAIL BREAKING AT THE LAG SCREW HOLE AND REQUIRED A CONVERSION TO ARCOS HEMI. DILIGENCE IS COMPLETED AND NO FURTHER INFORMATION ON THE REPORTED EVENT HAS BEEN PROVIDED.
Patient problems: Failure of Implant
MAUDE report 23422693 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K100238. One submission often covers many models, so check the product and lot details in each record.
- Z-0449-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail Left 130 Deg 11x300mm, Item Number 814611300 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramed
- Z-0454-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail 130 Deg 12x165mm, Item Number 816812165 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramedullar
- Z-0450-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail Left 125 Deg 9x165mm, Item Number 816709165 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramedu
- Z-0453-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail 130 Deg 10x165mm, Item Number 816810165 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramedullar
- Z-0447-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail Left Deg 9x300mm, Item Number 814609300 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramedullar
- Z-0448-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail Left 125 Deg 11x300mm, Item Number 814411300 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramed
- Z-0451-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail 125 Deg 10x165mm, Item Number 816710165 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramedullar
- Z-0452-2019 · Oct 2, 2018 · TerminatedAffixus Hip Fracture Nail 125 Deg 12x165mm, Item Number 816712165 The Affixus Hip Fracture Nail System, comprised of short and long nails, provides surgeons with an intramedullar
- Z-0141-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail Right 125 13 mm x 300 mm, Item Number 814313300 Product Usage: Intended for the fixation of fractures
- Z-0135-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail Right 125 11 mm x 420 mm, Item Number 814311420 Product Usage: Intended for the fixation of fractures
- Z-0158-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail 130 11 mm x 180 mm, Item Number 814511180 Product Usage: Intended for the fixation of fractures
- Z-0137-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail Right 125 11 mm x 460 mm, Item Number 814311460 Product Usage: Intended for the fixation of fractures
- Z-0140-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail Right 125 13 mm x 280 mm, Item Number 814313280 Product Usage: Intended for the fixation of fractures
- Z-0165-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail Left 130 11 mm x 360 mm, Item Number 814611360 Product Usage: Intended for the fixation of fractures
- Z-0125-2019 · Aug 8, 2018 · TerminatedAffixus Hip Fracture Nail Right 125 9 mm x 320 mm, Item Number 814309320 Product Usage: Intended for the fixation of fractures
…and 234 more.
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.