Adverse event reports
10
Deaths reported
0
Injuries reported
9
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00887868356018), received between Jan 31, 2023 and Sep 29, 2025 — classified as 9 injuries, 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 1 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem7
  • Insufficient Device Problem Information1
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Malposition of Device1

Patient problems

  • Bone Fracture(s)3
  • Bursitis3
  • Pain2
  • Aseptic loosening1
  • Discomfort1
  • Hematoma1
  • Insufficient Information1
  • Joint Dislocation1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjurySep 29, 2025Malposition of Device; Malposition of Device

    IT WAS REPORTED THAT THE PATIENT UNDERWENT AN INITIAL HIP PROCEDURE. SUBSEQUENTLY, THE PATIENT WAS REVISED APPROXIMATELY TWO MONTHS LATER DUE TO DISLOCATION AND CUP MALPOSITION. THE CUP WAS RETROVERTED. IT WAS REPORTED THAT NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Joint Dislocation

    MAUDE report 23166837 ↗
  • InjuryAug 26, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED ONGOING TROCHANTERIC BURSITIS REQUIRING CORTISONE INJECTIONS AT 11, 16, AND 19 MONTHS POSTOP. NO COMPLICATIONS CONCERNING THE IMPLANTS HAVE BEEN IDENTIFIED ON X-RAY. FOLLOW-UPS TO GATHER ADDITIONAL INFORMATION ARE CURRENTLY IN PROCESS.

    Patient problems: Bursitis; Pain

    MAUDE report 22893050 ↗
  • InjuryMay 26, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION PROCEDURE 2 DAYS POST IMPLANTATION DUE TO A PERI-PROSTHETIC FRACTURE FROM A FALL. THE X-RAY RESULTS ALSO SHOWED POSSIBLE LOOSENING OF THE ACETABULAR CUP. THE CUP REMAINS IMPLANTED. THERE IS NO FURTHER INFORMATION AVAILABLE AT THE TIME OF THIS REPORT

    Patient problems: Aseptic loosening

    MAUDE report 22084460 ↗
  • InjuryApr 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO FURTHER INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Bursitis; Pain

    MAUDE report 21784620 ↗
  • InjuryFeb 7, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION PROCEDURE DUE TO UNKNOWN REASONS.THERE IS NO ADDITIONAL INFORMATION AVAILABLE AT THIS TIME.

    Patient problems: Insufficient Information

    MAUDE report 21332867 ↗
  • MalfunctionJan 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THERE IS NO UPDATE TO THE PRIOR EVENT DESCRIPTION PROVIDED.

    Patient problems: Bone Fracture(s); Osteopenia/ Osteoporosis

    MAUDE report 21137650 ↗
  • InjuryDec 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO ADDITIONAL EVENT INFORMATION TO REPORT AT THIS TIME.

    Patient problems: Bursitis; Discomfort

    MAUDE report 20833342 ↗
  • InjuryOct 10, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO FURTHER INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Bone Fracture(s)

    MAUDE report 20416702 ↗
  • InjuryOct 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT APPROXIMATELY FIVE DAYS POST-IMPLANTATION, THE PATIENT UNDERWENT A HIP REVISION DUE TO A FRACTURE. PATIENT HAD A PROXIMAL FEMUR REPLACEMENT AND PELVIC FIXATION. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Bone Fracture(s)

    MAUDE report 20359295 ↗
  • InjuryJan 31, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT LEFT HIP JOINT DEBRIDEMENT APPROXIMATELY TWO WEEKS POST IMPLANTATION DUE TO EXCESSIVE DRAINAGE AND HEMATOMA. SUBSEQUENTLY, FIVE WEEKS POST-OP, THE PATIENT EXPERIENCED DELAYED HEALING OF THE LEFT TOTAL HIP ARTHROPLASTY WOUND. THE SURGEON UTILIZED THE PREVIOUS INCISION AND PERFORMED AN ARTHROTOMY. THE INCISION WAS ENTIRELY INTACT EXCEPT FOR A PIN HOLE AT THE CENTRAL PORTION. ONCE THE PIN HOLE WAS DISSECTED, THE SURGEON ENCOUNTERED A FLUID COLLECTION IN THE SUBCUTANEOUS REGION WITH A SMALL AMOUNT OF FATTY NECROSIS AND THE PRESENCE OF SEROUS FLUID. THREE CULTURES WERE OBTAINED AND SENT TO PATHOLOGY. THE WOUND WAS IRRIGATED AND DEBRIDED, AND THERE WAS NO PURULENCE OR EVIDENCE OF FRANK INFECTION PRESENT. A FORMAL ARTHROTOMY WAS THEN PERFORMED TO ENSURE ADEQUATE IRRIGATION AND DEBRIDEMENT WITH INTACT IMPLANTS NOTED. THE SURGEON REPORTED THAT THE EVENT WAS PROBABLY RELATED TO PROCEDURE; NOT RELATED TO DEVICE AND OR INSTRUMENTS. THE PATIENT HAD BEEN RECEIVING ROCEPHIN BUT WAS SWITCHED TO IV DAPTOMYCIN DUE TO RASH FROM ROCEPHIN. APPROXIMATELY ONE WEEK POST ARTHROTOMY, THE PATIENT WAS EVALUATED AT THE ER FOR DYSPNEA, TACHYCARDIA AND LEFT LEG PAIN. A

    Patient problems: Hematoma; Pulmonary Embolism; Unspecified Infection

    MAUDE report 16272594 ↗

FDA clearance and classification

Cleared through 510(k) K140669 on Dec 11, 2014 (decision: Substantially Equivalent). Submitted by Biomet, Inc. as “G7 Osseoti Acetublar Shells”. The FDA review took 268 days. FDA record ↗

The FDA regulates product code PBI (prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive) under 21 CFR 888.3310 as a Class II device. 21 CFR 888.3310 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the G7® Acetabular System 110010263

Has the G7® Acetabular System 110010263 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00887868356018), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the G7® Acetabular System 110010263?

The FDA's MAUDE database lists 10 adverse event reports for this device, received between Jan 31, 2023 and Sep 29, 2025. In those reports, the most common specific device problems are “Loosening of Implant Not Related to Bone-Ingrowth” (1) and “Malposition of Device” (1); the most common patient problems are “Bone Fracture(s)” (3), “Bursitis” (3) and “Pain” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the G7® Acetabular System 110010263?

None of the reports are classified as deaths, 9 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the G7® Acetabular System 110010263 FDA approved?

It was cleared through 510(k) K140669 on Dec 11, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the G7® Acetabular System 110010263 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the G7® Acetabular System 110010263, and is it still sold?

The FDA's device database lists Biomet Orthopedics, LLC as the company responsible for it (brand G7® Acetabular System, model 110010263). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive devices

All prosthesis, hip, constrained, cemented or uncemented, metal/polymer, + additive devices →

Sources and updates