- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867011625), received between Jul 19, 2017 and Jul 15, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Improper or Incorrect Procedure or Method1
Patient problems
- Bone Fracture(s)1
- Failure of Implant1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 15, 2024Break; Break
ON 04/24/2024: IT WAS REPORTED, BY A PATIENT VIA PHONE. THAT AFTER, UNDERGOING A DISTAL FEMUR OSTEOTOMY ON (B)(6) 2023, ONE OF THE SIX IMPLANTED SCREWS BROKE. THIS WAS DISCOVERED 3 1/2 MONTHS POST-OP IN AN X-RAY. ON (B)(6) 2023, WHEN THIS PROCEDURE TOOK PLACE, AN AR-13280-60, CANCELLEOUS SCREW; AN AR-13380-54, CORTICAL SCREW; AN AR-13280-60, CANCELLEOUS SCREW; AN AR-13380-50, CORTICAL SCREW; AN AR-13280-65, CANCELLEOUS SCREW AND AN AR-13380-46, CANCELLEOUS SCREW WERE IMPLANTED. IT HAS NOT BEEN CONFIRMED, WHICH SCREW BROKE. A POST-OP X-RAY WAS TAKEN 2 MONTHS, POST-OP WHERE EVERYTHING LOOKED GOOD. HOWEVER, THE X-RAY TAKEN 3 1/2 MONTHS POST, SHOWED A BROKEN SCREW THAT HAD PARTIALLY MADE ITS WAY. THE INTEGRITY OF THE HEALING BONE WILL DETERMINE, WHEN A REVISION WILL BE TAKING PLACE. ADDITIONAL INFORMATION, WAS PROVIDED BY THE PATIENT. WHERE HE STATED, THAT A TEST HAD BEEN RUN TO CONFIRM, THERE WERE NO DEFICIENCIES WITH HIS HEALTH, THAT WOULD CAUSE THIS FAILURE. THE PATIENT WILL BE UNDERGOING A REVISION SURGERY WITH A TRAUMA SURGEON. THERE PATIENT STATED, HIS FEMUR IS NOW SHORT ON BOTH SIDES, DUE TO THE BREAKAGE. ADDITIONAL INFORMATION, WAS PROVIDED ON 06/27/2024. WHERE THE PATIENT REPO
Patient problems: Failure of Implant
MAUDE report 19740473 ↗InjuryJul 19, 2017Improper or Incorrect Procedure or Method
IT WAS REPORTED THAT THE FIRST SCREW ((B)(4)) CAUSED A VERTICAL FRACTURE OF THE FEMUR. A TOTAL OF 7 SCREWS WERE USED; THE FRACTURE GOT LONGER WITH EACH SCREW. THE CASE WAS FINISHED AND CERCLAGE WIRE WAS USED TO HOLD THE FEMUR TOGETHER. FEMORAL OSTEOTOMY. NO ADDITIONAL HOSPITALIZATION WAS NEEDED. FOLLOW-UP INVESTIGATION: IT WAS REPORTED THAT DURING A FEMORAL OSTEOTOMY CASE THE CONTOURLOCK FEMORAL OSTEO SMALL RIGHT PLATE, AR-13110R-01 ((B)(4)) WAS USED. WHEN IMPLANTING THE FIRST CORTICAL SCREW, AR-13380-54 ((B)(4)) IN THE MOST DISTAL OF THE PROXIMAL HOLES THE FEMUR BEGAN TO FRACTURE. THE FRACTURE CONTINUED AS THE SCREWS WERE IMPLANTED DISTAL TO PROXIMAL. THE SCREWS WERE IMPLANTED AS FOLLOWS: AR-13380-50 ((B)(4)), AR-13380-46 ((B)(4)) AND AR-13380-36 ((B)(4)). THE CASE WAS COMPLETED USING ANOTHER MANUFACTURE'S 18 GAUGE WIRE (QTY. 2) TO SECURE THE FRACTURE IN CERCLAGE TECHNIQUE. AT THIS TIME THE PATIENT HAS NOT HAD A POST OP RECHECK. PATIENT IS MALE, (B)(6). NO ADDITIONAL HOSPITALIZATION WAS NEEDED.
Patient problems: Bone Fracture(s)
MAUDE report 6725285 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page