Arthrex® AR-1949Recalls & reported problems
Arthrex, Inc. · SPEAR,TRCR 2.8MM FASTAK II · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867024304), received between Jan 29, 2021 and Apr 25, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Device Fell1
- Material Fragmentation1
- Mechanical Jam1
Patient problems
- Foreign Body In Patient1
- Insufficient Information1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 25, 2022Break; Mechanical Jam
IT WAS REPORTED THAT DURING POSTERIOR STABILIZATION SURGERY THE 3MM SHAVER DRILL GOT STUCK INSIDE THE DRILL GUIDE WHEN DRILLING INTO BONE AND BREAKS THE SHAVER DRILL HANDPIECE CONNECTOR. ORIGINALLY SWAPPED THE SHAVER DRILL BUT THE GUIDE DAMAGED THIS DRILL ALSO. THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY. THE SURGERY WAS FINISHED SUCCESSFULLY WITH A NEW DEVICE WITH THE SAME PART NUMBER. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY.
Patient problems: Insufficient Information
MAUDE report 14194550 ↗MalfunctionJan 29, 2021Material Fragmentation; Device Fell
IT WAS REPORTED THAT SPEAR FOR 2.8 MM FASTAK, AR-1949, WAS BEING USED IN A BANKHART REPAIR. DURING USE, WHEN THE SURGEON DRILLED INTO THE GLENOID, PIECES OF METAL WERE GENERATED AND FELL INTO THE PATIENT'S BODY. THE SURGEON CLEANED INSIDE OF THE JOINT, BUT COULD NOT CONFIRM WHETHER ALL THE METAL PIECES WERE REMOVED. AR-1250FT WAS ALSO USED WHEN DRILLING. THE SURGERY WAS COMPLETED BY USING NEW PRODUCTS OF SAME PART NO.
Patient problems: Foreign Body In Patient
MAUDE report 11251314 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page