Arthrex® AR-2324BSLMRecalls & reported problems
Arthrex, Inc. · BIO SWIVELOCK SP, 4.75x24.5MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867026896), received between Oct 5, 2016 and Oct 5, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Remove1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 5, 2016Difficult to Remove
IT WAS REPORTED THAT DURING A ROTATOR CUFF REPAIR, THE AR-2324BSL (BIO-SWIVELOCK SP, 4.75 MM X 24.5 MM, SELF-PUNCHING) WAS USED. THE SURGEON ATTEMPTED TO INSERT THE ANCHOR THREE TIMES AND ON THE THIRD ATTEMPT THE SELF PUNCH TIP AND PART OF THE SWIVELOCK ANCHOR BECAME IMPLANTED AND COULD NOT BE REMOVED. THE SURGEON REPORTED TO THE SALES REP THAT WHAT REMAINED IN THE PATIENT WAS SECURE. THE SURGEON WAS ABLE TO TIE THE SUTURE FROM THE ANCHOR INTO THE ROTATOR CUFF AND BRING THE TENDON DOWN OVER THE IMPLANTED ANCHOR. SURGEON ALSO PLACED ANOTHER SWIVELOCK AND INCORPORATED IT INTO THE REPAIR. SALES REP STATES IT IS UNCLEAR IF THE ADDITIONAL ANCHOR WAS "BUDDIED UP" OR PLACED CLOSE TO THE BROKEN ANCHOR. IT WAS REPORTED THAT THE SURGEON FELT EVERYTHING WAS SECURE. CASE WAS COMPLETED AS PLANNED. NO X-RAYS WERE TAKEN.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6000519 ↗
Other FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE devices
- GRYPHON ORTHOCORD 210813Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE712 reports
- HEALIX ADVANCE 222330Depuy Mitek, LLC · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE1 recall607 reports
- HEALIX ADVANCE ORTHOCORD 222295Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE640 reports
- HEALICOIL 72205137Smith & Nephew, Inc. · Fastener, fixation, biodegradable, soft tissue427 reports
- HEALIX ADVANCE ORTHOCORD 222296Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE320 reports
- TWINFIX 72202597Smith & Nephew, Inc. · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE288 reports
- Arthrex® AR-2324BCCArthrex, Inc. · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE254 reports
- HEALIX ADVANCE 222331Depuy Mitek, LLC · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE1 recall196 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page