Arthrex® AR-2324SLMRecalls & reported problems
Arthrex, Inc. · TITANIUM SWIVELOCK, 4.75x24.5MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00888867026940), received between Feb 22, 2021 and Dec 8, 2025 — classified as 9 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break4
- Detachment of Device or Device Component3
- Material Split, Cut or Torn2
- Failure to Advance1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Insufficient Information3
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Failure of Implant1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 8, 2025Material Split, Cut or Torn; Material Split, Cut or Torn
ON 11/17/2025, IT WAS REPORTED BY AN ARTHREX SUBSIDIARY EMPLOYEE VIA (B)(4) THAT AN AR-2324SLM 4.75 MM X 24.5 MM SELF PUNCHING, VENTED, SUTURE ANCHOR, SWIVELOCK SUTURE THAT HOLDS THE TIP OF THE ANCHOR WAS CUT WHEN USING THE ANCHOR. THIS WAS DISCOVERED DURING USE WITH NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23743465 ↗MalfunctionJan 6, 2025Break; Break
ON 12/09/2024, IT WAS REPORTED BY A ARTHREX SUBSIDIARY EMPLOYEE VIA SEMS-06730337 THAT AN AR-2324SLM SWIVELLOCK SUTURE BROKE. THIS OCCURRED DURING USE IN A ROTATOR CUFF REPLACEMENT CASE WITH NO PATIENT EFFECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21079097 ↗MalfunctionNov 14, 2024Break; Break
ON (B)(6) 2024, IT WAS REPORTED BY AN ARTHREX SUBSIDIARY EMPLOYEE VIA (B)(4) THAT AN AR-2324SLM SUTURE ANCHORS SUTURE WAS CUT AND THE ANCHOR WAS RELEASED. THIS OCCURRED DURING A ROTATOR CUFF REPAIR, THAT WAS COMPLETED USING ANOTHER PRODUCT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20683915 ↗MalfunctionMay 15, 2024Material Split, Cut or Torn; Material Split, Cut or Torn
ON (B)(6) 2022, IT WAS REPORTED BY A DISTRIBUTOR VIA EMAIL THAT AN AR-2324SLM SWIVELOCK SUTURES GOT CUT WHEN THE ANCHOR WAS PLACED AND THE BODY OF THE ANCHOR WAS LOWERED TO BE TIED. THIS WAS DISCOVERED DURING A PROCEDURE ON (B)(6) 2022. ADDITIONAL INFORMATION REQUESTED.
Patient problems: Insufficient Information
MAUDE report 19323459 ↗MalfunctionMay 6, 2024Failure to Advance; Failure to Advance
ON 12/14/2021, IT WAS REPORTED BY A DISTRIBUTOR VIA E-MAIL THAT A AR-2324SLM SWIVELOCK IS NOT WORKING. THIS OCCURRED ON (B)(6) 2021 DURING A PROCEDURE WHEN THE SURGEON INSERTED THE ANCHOR IT WOULD NOT GO DOWN AFTER IMPACTING AND ROLLING THE HANDLE. NO ADDITIONAL INFORMATION. ADDITIONAL INFORMATION REQUESTED. ADDITIONAL INFORMATION PROVIDED ON 12/15/2021 : THE PROCEDURE BEING PERFORMED WAS A ROTATOR CUFF REPAIR, AND THE CASE WAS COMPLETED USING A NON-ARTHREX DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19248418 ↗MalfunctionApr 26, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
ON (B)(6) 2022, IT WAS REPORTED BY AN ARTHREX EMPLOYEE VIA EMAIL THAT AN AR-2324SLM SWIVELOCK ANCHOR SEPARATED FROM SUTURE. THIS WAS DISCOVERED POST OPERATION VIA X-RAY. THE PROCEDURE PERFORMED WAS AN REDUCTION AND FIXATION OF AVULSION FRACTURE OF THE GREATER TUBEROSITY OF HUMERUS AND IT TOOK PLACE ON (B)(6) 2022. A REVISION SURGERY HAS NOT YET OCCURRED BUT IT WILL BE SCHEDULE FOR THE NEAR FUTURE. NO FURTHER INFORMATION HAS BEEN GIVEN AS OF TODAY. ADDITIONAL INFORMATION RECEIVED ON 5/9/2022: SURGEON BECAME AWARE OF DEVICE FAILURE THREE DAYS AFTER THE PROCEDURE ON (B)(6) 2022. REVISION SURGERY HAS YET TO BE SCHEDULE.
Patient problems: Failure of Implant
MAUDE report 19195817 ↗MalfunctionApr 25, 2024Break; Break
IT WAS REPORTED ON (B)(6) 2022 BY A FACILITY REPRESENTATIVE VIA EMAIL THAT AN AR-2324SLM SUTURE ANCHOR SUTURE BROKE. THIS WAS DISCOVERED DURING CASE WITH NO PATIENT HARM. PER FACILITY: "THE SUTURES ARE BETRAYED GENTLY, AND AT THE MOMENT OF FIXING THE ANCHORS, ONE OF THE SUTURES IS CUT (IT BREAKS)"
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19179833 ↗MalfunctionMar 13, 2023Detachment of Device or Device Component; Detachment of Device or Device Component
ON 2/20/2023, IT WAS REPORTED BY A DISTRIBUTOR VIA EMAIL THAT AN AR-2324SLM SWIVELOCK SP EYELET TIP OF THE ANCHOR IS RELEASED WHILE THE SUTURE IS TAUT FOR THE DOUBLE ROW AND IT IS NOT FULLY INSERTED, LEAVING THE TIP OUTSIDE THE INSERTION SITE. THIS WAS DISCOVERED DURING A PROCEDURE ON (B)(6) 2022.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Insufficient Information
MAUDE report 16528633 ↗MalfunctionFeb 22, 2021Break; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A ROTATOR CUFF REPAIR, WHEN THE SURGEON IMPLANTED THE AR-2324SLM , THE ANCHOR BROKE AND COMES OFF WHEN SCREWING. ALL FRAGMENTS WERE REMOVED AND THE CASE WAS COMPLETED BY USING ANOTHER AR-2324SLM WITHOUT FURTHER ISSUE.
Patient problems: Insufficient Information
MAUDE report 11358067 ↗
Other FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE devices
- GRYPHON ORTHOCORD 210813Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE712 reports
- HEALIX ADVANCE 222330Depuy Mitek, LLC · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE1 recall607 reports
- HEALIX ADVANCE ORTHOCORD 222295Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE640 reports
- HEALICOIL 72205137Smith & Nephew, Inc. · Fastener, fixation, biodegradable, soft tissue427 reports
- HEALIX ADVANCE ORTHOCORD 222296Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE320 reports
- TWINFIX 72202597Smith & Nephew, Inc. · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE288 reports
- Arthrex® AR-2324BCCArthrex, Inc. · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE254 reports
- HEALIX ADVANCE 222331Depuy Mitek, LLC · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE1 recall196 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.