Arthrex® AR-5025B-22Recalls & reported problems
Arthrex, Inc. · BIO-COMPRESSION SCREW 3 X 22MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867034716), received between Aug 11, 2016 and Feb 27, 2023 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- Device Embedded In Tissue or Plaque1
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 27, 2023Break
ON (B)(6) 2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT AN AR-5025B-22 BIO-COMPRESSION SCREW,3.0MM BY 22MM, AND AN AR-5025B-26 BIO-COMPRESSION SCREW, 3.0MM BY 26MM, SNAPPED IN HALF DURING INSERTION. CASE WAS COMPLETED BY USING A PRODUCT FROM ANOTHER MANUFACTURER.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 16444469 ↗InjuryAug 11, 2016Break
IT WAS REPORTED THAT DURING AN OCD LESION MICRO-FRACTURE PROCEDURE THE SURGEON USED THE K-WIRE, PREDRILLED AND PRE-TAPPED. HALFWAY THROUGH INSERTION, THE IMPLANT AR-5025B-24 LOT 10042879 ((B)(4)) BROKE. THE SCREW WAS REMOVED BUT FRAGMENTS REMAINED IN THE PATIENT. THE SURGEON TRIED A SECOND SMALLER IMPLANT AR-5025B-22 LOT 10033308 ((B)(4)) AND THE SAME ISSUE OCCURRED, LEAVING FRAGMENTS IN THE PATIENT. A THIRD SMALLER IMPLANT AR-5025B-20 LOT 1217167 ((B)(4)) WAS ATTEMPTED AND THIS ONE ABOUT 1/4 OF THE WAY DOWN THE THREADS BEGAN TO COMPRESS AND SURGEON CHOSE TO REMOVE THE SCREW WHILE STILL WHOLE. THE SURGEON COMPLETED THE CASE WITH K-WIRES. PATIENT WAS A (B)(6) FEMALE.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 5868146 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.