Arthrex® AR-7000-32Recalls & reported problems
Arthrex, Inc. · CANN SCRW,3.75X 32MMPT THRDED · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867041011), received between Dec 14, 2016 and Dec 14, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Bent” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Bent1
Patient problems
- Seizures1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 14, 2016Bent
IT WAS REPORTED THAT THE PATIENT UNDERWENT A LEFT LATERJET PROCEDURE ON (B)(6) 2016, WHERE A 3.75X32MM CANNULATED PARTIALLY THREADED SCREW (AR-7000-32, LOT: 1457740, (B)(4)) WAS IMPLANTED ALONG WITH A 3.75X30MM CANNULATED PARTIALLY THREADED SCREW (AR-7000-30, LOT: 1457565, (B)(4)). ON AN UNKNOWN DATE, THE PATIENT SUFFERED FROM A SEIZURE CAUSING THE AR-7000-32 TO BEND. A REVISION SURGERY TOOK PLACE ON (B)(6) 2016 AND THE PATIENT HAD THE AR-7000-32, LOT: 1457740, EXPLANTED AND REPLACED WITH AN AR-7000-34, LOT: 1457742. THE AR-7000-30, LOT: 1457565, WAS ALSO EXPLANTED AND REPLACED WITH AN AR-7000-32, LOT: 10034143. PATIENT IS A (B)(6) FEMALE. NO PATIENT INJURY.
Patient problems: Seizures
MAUDE report 6173241 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page