Arthrex® AR-8827-18Recalls & reported problems
Arthrex, Inc. · LO-PRO SCRW TM SS 2.7X 18MMCORTEX · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888867046771), received between Sep 6, 2024 and Apr 22, 2026 — classified as 3 injuries.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem2
- Adverse Event Without Identified Device or Use Problem1
- Defective Device1
Patient problems
- Pain2
- Bone Fracture(s)1
- Failure of Implant1
- Foreign Body Reaction1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryApr 22, 2026Patient Device Interaction Problem
ON 02-JAN-2025, A PATIENT CALLED IN REPORTING THAT AFTER UNDERGOING AN ANKLE PROCEDURE ON (B)(6) 2025, SHE HAD EXPERIENCED A REACTION, ALONG WITH EXPERIENCING HER SKIN CHANGING, AND PAIN NEAR HER ANKLE. ADDITIONAL INFORMATION WAS PROVIDED ON 24-MAR-2026 WHERE THE PATIENT REPORTED THAT SHE UNDERWENT A LEFT ANKLE PROCEDURE FOR A DISPLACED BIMALLEOLAR FRACTURE OF THE LOWER LEG ON (B)(6) 2025 WHERE AN AR-8943DL-04 LOCKING DISTAL FIBULA PLATE, AR-8827-18 LOW PROFILE SCREW¿, 2.7 X 18 MM, (3) AR-8827CL-12 KREULOCK¿ COMPRESSION SCREW, SS, 2.7 MM X 12 MM, AR-8827CL-14 KREULOCK¿ COMPRESSION SCREW, SS, 2.7 MM X 14 MM, (2) AR-8827CL-16 KREULOCK¿ COMPRESSION SCREW, SS, 2.7 MM X 16 MM, (3) AR-8835CL-12 KREULOCK¿ COMPRESSION SCREW, SS, 3.5 MM X 12 MM, AR-8835-14 LOW PROFILE SCREW¿, SS, 3.5 X 14 MM, CORTICAL, AND AN AR-8925SS SYNDESMOSIS TIGHTROPE® XP, STAINLESS STEEL WERE IMPLANTED. THE PATIENT BEGAN TO EXPERIENCE THE FOLLOWING SYMPTOMS ON (B)(6) 2025; RUNNY NOSE, DIARRHEA, BLURRED VISION, SENSITIVITY TO THE ANKLE, BOTTOM OF THE TOES ACHE, CHANGES IN SKIN, BLOOD PRESSURE GOING UP AND DOWN, BACK OF HEELS ACHE, ITCHY ANKLE; THAT IS BEING TREATED WITH A CREAM, SHARP PAIN IN THE ANKLE, RIGHT EAR BLOC
Patient problems: Foreign Body Reaction; Pain
MAUDE report 24956989 ↗InjuryJul 8, 2025Defective Device; Adverse Event Without Identified Device or Use Problem; Defective Device; Adverse Event Without Identified Device or Use Problem
ADDITIONAL INFORMATION WAS RECEIVED ON 07/08/2025: THE AR-8973DS FIBULOCK IMPLANT SYSTEM HAD THE END CAP IN THE KIT INSERTED INTO THE FIBULOCK NAIL DURING THE INITIAL PROCEDURE. DURING THE ROH/TTC REVISION, THE END CAP WAS REMOVED BEFORE THE EXTRACTION OF THE BROKEN FIBULAR NAIL. THE END CAP FROM THE AR-8973DS FIBULOCK IMPLANT SYSTEM DID NOT BREAK DURING THE PROCEDURE.
Patient problems: Bone Fracture(s); Failure of Implant
MAUDE report 22439189 ↗InjurySep 6, 2024Patient Device Interaction Problem; Patient Device Interaction Problem
ON (B)(6) 2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT A PATIENT UNDERWENT REVISION SURGERY DUE TO PAIN. ON (B)(6) 2023, THE PATIENT UNDERWENT SURGERY FOR AN ANKLE FRACTURE AND SYNDESMOSIS REPAIR. DURING THE PROCEDURE, TWO AR-8730-36PT LOW PROFILE SCREW, TI, 3.0 MM X 36 MM, CANCELLOUS, PARTIALLY THREADED, AN AR-8827-18 LOW PROFILE SCREW, 2.7 X 18 MM, CORTEX, AN AR-8827-22 LOW PROFILE SCREW, 2.7 X 22 MM, CORTEX, AN AR-8973DS FIBULOCK IMPLANT SYSTEM, AN AR-8973L-38-180 ARTHREX FIBULOCK NAIL, 3.8 X 180 MM LEFT, AND AN AR-8925SS SYNDESMOSIS TIGHTROPE XP, STAINLESS STEEL WERE IMPLANTED. POST-OPERATIVE, THE PATIENT STARTED TO EXPERIENCE PAIN. ON (B)(6) 2024, REVISION SURGERY WAS PERFORMED TO REMOVE ALL THE IMPLANTS EXCEPT FOR THE AR-8973L-38-180 ARTHREX FIBULOCK NAIL. DURING THE REMOVAL OF THE IMPLANTS, THE DISTAL END OF THE EXTRACTION TOOL OF AN AR-8973RK FIBULOCK REMOVAL KIT BROKE OFF AFTER ROUGHLY 8 MALLET STRIKES. ANOTHER AR-8973RK FIBULOCK REMOVAL KIT WAS OPENED, AND THE SAME THING OCCURRED. THE EXTRACTION TOOLS BROKE, BUT NO PIECES WERE IN THE PATIENT. THE SURGEON ELECTED TO CLOSE AND FINISH THE CASE WITH THE NAIL STILL IMPLANTED AND FELT CONFIDENT THAT THE REMOVE
Patient problems: Pain
MAUDE report 20156936 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page