Arthrex® AR-8835-34Recalls & reported problems
Arthrex, Inc. · LO-PRO SCRW TM,SS 3.5X 34MMCORT · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867047389), received between Jan 26, 2021 and Jan 26, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 26, 2021Break
IT WAS REPORTED THAT DURING A TIBIA AND FIBULA OSTEOTOMY (ANKLE FRACTURE) PROCEDURE (B)(6) 2021 THE SURGEON WAS INSERTING A 3.5 CORTICAL SCREW, AR-8835-34 (LOT UNKNOWN), AND THE HEAD OF THE CORTICAL SCREW BROKE OFF. THE DRIVER AR-8943-12 (LOT 4751509) BEING USED DID NOT BREAK, JUST THE SCREW HEAD BROKE OFF. THE BONE SOCKET WAS PREPARED PROPERLY USING A 2.5 DRILL BIT (AR-8943-42) AND A LOCKING TOWER FOR PREPARATION FOR SCREW INSERTION. SURGEON FOLLOWED BY USING TWO T15 DRIVERS, ONE ON POWER FOLLOWED BY HAND. THE BONE QUALITY WAS REPORTED TO BE GOOD. THE SURGEON WAS ABLE TO USE A LOCKING SCREW PROXIMAL TO WHERE THE BROKEN SCREW WAS PLACED. THE CASE WAS COMPLETED.
Patient problems: Insufficient Information
MAUDE report 11228598 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page