Arthrex, Inc. · MINI TIGHTROPE FT · Class 2 · Implant

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888867048850), received between Oct 21, 2016 and Dec 12, 2023 — classified as 3 injuries.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Detachment Of Device Component2
  • Entrapment of Device2

Patient problems

  • Foreign Body In Patient2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 12, 2023Break; Break

    ON 11/13/2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA PHONE THAT AN AR-8912DS MINI TIGHTROPE FIBERWIRE SNAPPED WHEN UNDER TENSION. THIS WAS DISCOVERED DURING USE IN A CASE WITH NO PATIENT EFFECT. CASE COMPLETED BY FILLING BONE VOID WITH ALLOSYNC. DELAY OVER 15 MINUTES.C THE DEVICE WAS NOT REPLACED, THE SURGEON WAS ABLE TO TETHER OFF OF ANOTHER TIGHTROPE THAT WORKED. DELAY WAS A DEVIATION FROM THE PROCEDURE TO USE ALLOSYNC, WHICH IS NOT COMMON TO A LISFRANK PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18314314 ↗
  • InjuryMay 3, 2018Break; Detachment Of Device Component; Entrapment of Device

    IT WAS REPORTED THAT THE SURGEON WAS USING THE TIGHTROPE FT FOR A LISFRANC REPAIR. HE PLACED THE WIRE, DRILLED WITH THE 2.7MM DRILL AND THEN THE 4.5MM DRILL. HE THEN TAPPED (ON POWER AS NO HANDLE WAS AVAILABLE), CHECKING EVERYTHING UNDER FLUROSCOPY. HE THEN STARTED TO INSERT THE BIO TIGHTROPE FT AND HEARD A CLICK AND FELT THE SCREWDRIVER DISENGAGE. HE CHECKED WITH FLUROSCOPY AND SAW THAT THE TIP OF THE DRIVER HAD SNAPPED OFF. THE SCREW WAS HOLDING, BUT MAY NOT HAVE BEEN ALL THE WAY ACROSS THE JOINT. THERE WAS NO HARM FOR THE PATIENT, OPERATOR OR THIRD PARTY. THE SURGERY WAS FINISHED SUCCESSFULLY. THE SURGEON COULD NOT DO ANYTHING ELSE, SO LEFT IT IN PLACE.. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY. FOLLOW-UP INVESTIGATION: THE TIP/DRIVER PART OF THE SCREWDRIVER, WHICH SITS INSIDE THE SCREW BROKE-OFF AND REMAINS IN THE PATIENT. NOTHING ELSE BROKE OFF, SO IT IS JUST THE METAL PART OF THE SCREWDRIVER THAT IS IN THE PATIENT. THE SURGEON WAS HAPPY WITH THE REDUCTION AND COULD NOT SEE ANYWAY TO REMOVE THE DRIVER TIP THAT WAS LEFT BEHIND.

    Patient problems: Foreign Body In Patient

    MAUDE report 7483534 ↗
  • InjuryOct 21, 2016Break; Detachment Of Device Component; Entrapment of Device

    IT WAS REPORTED THAT DURING A LIS FRANC DISLOCATION REPAIR PROCEDURE, THE SURGEON PLACED A REGULAR TIGHTROPE FOR INITIAL FIXATION WITH NO ISSUES, HOWEVER, WHEN HE WENT TO APPLY THE MINI TIGHTROPE FT, THE SCREWDRIVER FELT AS IF IT WAS GETTING WEAK OR THE ANCHOR WAS STRIPPING. THE SURGEON PULLED THE ANCHOR OUT AND RE-INSERTED WHEN THE TIP OF THE DRIVER BROKE-OFF INTO THE SCREW. THE TIP OF THE DRIVER WAS LEFT INSIDE OF THE SCREW TO AVOID A 2ND INCISION AND POSSIBLE HARM TO THE PATIENT. THE TIP OF THE DRIVER IS CLEARLY VISIBLE ON THE PATIENT'S X-RAY. THE TIGHTROPE MECHANISM WAS STILL INTACT. THE BUTTON WAS SLID DOWN TO THE BONE AND REDUCTION WAS ACHIEVED TO COMPLETE THE CASE. FINAL X-RAYS SHOWED THE DISLOCATION HAD BEEN REDUCED. PATIENT IS A (B)(6) MALE.

    Patient problems: Foreign Body In Patient

    MAUDE report 6048636 ↗

Other WASHER, BOLT NUT devices