Arthrex® AR-8933-18Recalls & reported problems
Arthrex, Inc. · LO-PRO SCRW,TI,3.0MMX 18MMCORT · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867049536), received between Mar 5, 2019 and Mar 5, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Patient Device Interaction Problem1
- Patient-Device Incompatibility1
Patient problems
- Device Embedded In Tissue or Plaque1
- Necrosis1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 5, 2019Patient-Device Incompatibility; Patient Device Interaction Problem; Patient-Device Incompatibility; Patient Device Interaction Problem
IT WAS REPORTED BY THE PATIENT¿S LEGAL REPRESENTATIVE THAT THE PATIENT UNDERWENT A LEFT 1ST METATARSOPHALANGEAL JOINT REVISION FUSION AND HARDWARE REMOVAL, EXTRACTION OF GRAFT AND WEIL OSTEOTOMY ON (B)(6) 2017 DUE TO PAINFUL NONUNION OF HER LEFT FIRST METATARSOPHALANGEAL JOINT FUSION. DURING THE PROCEDURE THE SURGEON EXPLANTED A PLATE AND LAG SCREWS FROM A PREVIOUS PROCEDURE (DATE OF PREVIOUS PROCEDURE AND EXPLANTED DEVICE MANUFACTURER UNKNOWN AT TIME OF INITIAL REPORT). THE SURGEON UTILIZED A 1.7 MM DRILL BIT, AR-1201-7DC, FOR MICRO DRILLING THROUGH THE FUSION SITE IN ORDER TO PROMOTE INGROWTH AND THE DRILL BIT SNAPPED OFF INTRAMEDULLARY. THE SURGEON ATTEMPTED TO REMOVE THE DRILL BIT FRAGMENT BUT WAS UNABLE TO BECAUSE OF THE LOCATION. THE OPERATIVE REPORT DATED (B)(6) 2017 NOTED THAT REMOVAL OF THE DRILL BIT FRAGMENT WOULD CAUSE MORE HARM TO THE PATIENT. THE SURGEON FINISHED THE SURGERY BY PERFORMING A CAPSULOTOMY AND WEILL OSTEOTOMY AND IMPLANTED THE FOLLOWING ARTHREX PLATE AND SCREWS: AR-8944CL-L (LOW PROFILE MTP PLATE), AR-8730-38PT (QUICKFIX SCREW), AR-8933-24 (LOW PROFILE SCREW), AR-8933-18 (LOW PROFILE SCREW), AND AR-8933L-18 (QTY 2) (LOW PROFILE LOCKING SCREW). IN (B)(6) 20
Patient problems: Device Embedded In Tissue or Plaque; Necrosis; Pain
MAUDE report 8391609 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page