Arthrex® AR-8933L-14Recalls & reported problems
Arthrex, Inc. · LO-PRO LOCK SCRW,TI,3.0MMX 14MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867050020), received between Jul 14, 2017 and Jul 14, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Detachment Of Device Component1
Patient problems
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 14, 2017Break; Detachment Of Device Component
IT WAS REPORTED THAT THE PATIENT UNDERWENT A LAPIDUS BUNIONECTOMY ON (B)(6) 2015 CEDAR MEDICAL CENTER IN WHICH A PLATE AND 5 SCREWS WERE IMPLANTED IN HER LEFT FOOT. THE PATIENT BEGAN TO EXPERIENCE FOOT PAIN BEGINNING IN THE INCISION AREA AND RADIATING OUTWARD IN (B)(6) 2017. THE PATIENT IS SCHEDULED TO HAVE THE PLATE AND 5 SCREWS EXPLANTED ON (B)(6) 2017 AS THE BONE HAS FUSED . FOLLOW INVESTIGATION: SURGEON PERFORMED A SECOND SURGERY ON (B)(6) 2017 WHERE HE EXPLANTED THE FOLLOWING DEVICES WHICH HAD BEEN IMPLANTED DURING THE (B)(6) 2015 PROCEDURE: AR-8952TT-03 QTY 1, AR-8933L-14 QTY 2, AR-8933L-12 QTY 2, AR-8933L-24 QTY 1. THE PATIENT ALSO HAD AN AR-8730-34H FULLY THREADED MINI COMPRESSION SCREW FROM THE ORIGINAL PROCEDURE THAT THE SURGEON CHOSE TO LEAVE IN THE PATIENT. DURING THE (B)(6) 2017 SURGERY, THE SURGEON WAS USING A HEXALOBE DRIVER TO REMOVE THE SCREWS AND THE TIP OF THE DRIVER BROKE OFF. THE TIP WAS RETRIEVED WITH FORCEPS AND THE CASE WAS COMPLETED.
Patient problems: Pain
MAUDE report 6714789 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page