The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867050044), received between Dec 15, 2016 and Dec 15, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Operates Differently Than Expected1
- Failure To Adhere Or Bond1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 15, 2016Failure To Adhere Or Bond; Device Operates Differently Than Expected
IT WAS REPORTED THAT THE PATIENT HAD UNDERGONE A PREVIOUS 2ND TMT FUSION ON (B)(6) 2015. THE SURGEON WAS PERFORMING A 2ND TMT FUSION REVISION SURGERY ON (B)(6) 2016 DUE TO NON-UNION DURING WHICH THE FOLLOWING DEVICES WERE EXPLANTED: AR-8952TT-04, LOT 6791406 (CC100071 LINE (B)(4)), AR-8933L-24, LOT W38572 (CC100071 LINE (B)(4)), AR-8933L-16, LOT 1437750 (CC100071 LINE (B)(4)), AR-8933-26, LOT 157946 (QTY 2) (CC100071 LINE (B)(4)) AND AR-8933-28, LOT 139580 (CC100071 LINE (B)(4) ). TO COMPLETE THE REVISION PROCEDURE THE SURGEON WAS IMPLANTING AN AR-8952MS-07, 2.4MM 7 HOLE LOW PROFILE STRAIGHT PLATE (CC100071 LINE(B)(4)) ALONG WITH AN AR-8724L-18, 2.4MM X 18MM LOW PROFILE LOCKING SCREW (CC100071 LINE (B)(4)) WERE BEING IMPLANTED IN THIS REVISION SURGERY. A 1.7MM DRILL WAS USED TO CREATE THE PILOT HOLES FOR THE SCREWS. THE SURGEON SECURED THE PLATE WITH BB TAKS. HE THEN INSERTED A 2.4MM LOCKING SCREW, AND THE SCREW HAD CUT THROUGH THE PLATE AND DID NOT LOCK IN. THE 2.4MM PLATE WAS REMOVED AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A 3.0 MM STRAIGHT MTP PLATE AND SCREWS. NO PATIENT INJURY REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6178008 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page