Arthrex® AR-8933V-14Recalls & reported problems
Arthrex, Inc. · 3.0 X 14MM VAL SCREW, Ti · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888867050228), received between Aug 17, 2023 and Aug 4, 2025 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Failure to Advance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Advance1
- Fitting Problem1
- Patient Device Interaction Problem1
Patient problems
- Insufficient Information2
- Hypersensitivity/Allergic reaction1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 4, 2025Failure to Advance; Failure to Advance
ON 7/15/2025, A SALES REPRESENTATIVE REPORTED VIA EMAIL THAT ONE AR-8933V-14 LOW PROFILE VA LOCKING SCREW, ONE AR-8933V-16 LOW PROFILE VA LOCKING SCREW, AND TWO AR-8933V-18 LOW PROFILE VA LOCKING SCREWS WERE UNSUCCESSFULLY THREADED THROUGH A LOCKING DISTAL FIBULAR PLATE, DESPITE APPROPRIATE DRILLING TECHNIQUES. AS A RESULT, ALL FOUR SCREWS WERE DISCARDED, AND THE PLATE HOLE REMAINED UNFILLED. THIS WAS DISCOVERED DURING AN ORIF ANKLE PROCEDURE ON (B)(6) 2025. ADDITIONAL INFORMATION WAS RECEIVED ON 07/21/2025: ON (B)(6) 2025, DURING AN ORIF ANKLE PROCEDURE, AN AR-9943BL-05 LOCKING DISTAL FIBULA PLATE WAS IMPLANTED AND REMAINS IN THE PATIENT. THERE WAS NO REPORT OF IMPLANT BREAKAGE DURING THE INCIDENT. THE PROCEDURE WAS DELAYED BY APPROXIMATELY 10 MINUTES DUE TO DIFFICULTY ENGAGING THE SCREWS, WHICH REQUIRED REDRILLING AND REINSERTION. ADDITIONAL ANESTHESIA WAS ADMINISTERED TO ACCOMMODATE THE EXTENDED OPERATIVE TIME. AN AR-8933GV DRILL GUIDE AND AN AR-8943-16 2.0 MM DRILL BIT WERE USED TO PREPARE THE BONE SOCKET FOR IMPLANT PLACEMENT. BONE QUALITY WAS ASSESSED AS ADEQUATE, AND NO PHOTOGRAPHS WERE TAKEN TO DOCUMENT THE ISSUE.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 22698659 ↗MalfunctionDec 8, 2023Fitting Problem; Fitting Problem
ON (B)(6) 2023, IT WAS REPORTED BY A SALES REP. VIA EMAIL THAT AN AR-8933V-14, LOW PROFILE VA LOCKING SCREW, 3.0 X 14 MM, TI, WAS NOT ABLE TO LOCK INTO THE PLATE. THE SURGEON TRIED TO REAM AND MEASURE AGAIN AND DRILLED THROUGH VAL DRILL GUIDE AND ALL THE APPROPRIATE INSTRUMENTS WERE USED TO INSERT THE SCREW. ON 15/11/2023 - UPON FURTHER CLARIFICATION WITH SALES REP, THIS WAS DISCOVERED DURING USE IN A MTP FUSION PROCEDURE ON (B)(6) 2023. THE PROCEDURE WAS COMPLETED SUCCESSFULLY AS THE SURGEON FIXED ALL THE OTHER SCREWS EXCEPT THE ONE SEEN IN THE X-RAY.
Patient problems: Insufficient Information
MAUDE report 18292744 ↗InjuryAug 17, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED, THAT THE PATIENT UNDERWENT SURGERY ON (B)(6) 2018. FOR AN OPEN REDUCTION INTERNAL FIXATION OF A LEFT TRIMALLEOLAR ANKLE FRACTURE, WITH FIXATION OF THE DISTAL FIBULA FRACTURE, POSTERIOR MALLEOLUS FRACTURE, AND SYNDESMOTIC FIXATION. DURING THE (B)(6) 2018 SURGERY, THE FOLLOWING PRODUCTS WERE USED AND/OR IMPLANTED: AR-8740-52PTS, QCKFIX SCRW, TI, CANN ST, CANC.,4.0X 52MM, LOT/SERIAL#: (B)(6); AR-8925T K-LESS, T-ROPE W/DRV, SYN REPR, TI, LOT/SERIAL#: (B)(6); AR-8933-20, LO-PRO SCRW, TI, 3.0MMX 20MMCORT, LOT/SERIAL#: (B)(6); AR-8933V-12, 3.0 X 12MM VAL SCREW, TI, LOT/SERIAL#: (B)(6); AR-8933V-14, 3.0 X 14MM VAL SCREW, TI, LOT/SERIAL#: (B)(6); AR-8933V-16, 3.0 X 16MM VAL SCREW, TI, LOT/SERIAL#: (B)(6); AR-8933V-18, 3.0 X 18MM VAL SCREW, TI, LOT/SERIAL#: (B)(6); AR-8933V-20, 3.0 X 20MM VAL SCREW, TI, LOT/SERIAL#: (B)(6); AR-8935-12, LO-PRO SCRW, TI, 3.5MMX 12MM, LOT/SERIAL#: (B)(6); AR-8935-14, LO-PRO SCRW, TI, 3.5MMX 14MM, LOT/SERIAL#: (B)(6); AR-8935-14, LO-PRO SCRW, TI, 3.5MMX 14MM, LOT/SERIAL#: (B)(6); AR-8935-26, LO-PRO SCRW, TI, 3.5MMX 26MM, LOT/SERIAL#: (B)(6); AR-8943-01, GUIDE WIRE, TROCAR TIP, 1.35 MM, LOT/SERIAL#: (B)(6); AR-8943-02, DRILL BIT, CANNULATED, 2.6M
Patient problems: Hypersensitivity/Allergic reaction
MAUDE report 17563008 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page