Arthrex® AR-8951MRRecalls & reported problems
Arthrex, Inc. · LISFRANC PLATE, MEDIUM, RIGHT, TI · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867054813), received between Sep 5, 2024 and Sep 5, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 5, 2024Break; Break
ON 8/12/2024, IT WAS REPORTED BY A PATIENT VIA EMAIL THAT A CANCELLOUS COMPRESSION SCREW, BEING USED WITH A TROCAR TIP TO STABILIZE A LISFRANC INJURY, BROKE OFF IN THE FOOT. THE BROKEN FRAGMENTS WERE NOT REMOVED. ON (B)(6) 2024, THE PATIENT REPORTED THAT THE PROCEDURE TOOK PLACE ON (B)(6) 2024 IN WHICH AN AR-8935CL-26 KREULOCK COMPRESSION SCREW, AN AR-8935-22 NON-LOCKING LOW PROFILE SCREW, AN AR-8935CL-32 KREULOCK COMPRESSION SCREW, AND AN AR-8951MR MEDIUM RIGHT LISFRANC PLATE WAS IMPLANTED. ADDITIONALLY, ANOTHER PLATE AND 5 SCREWS WITH UNKNOWN PART NUMBERS WERE ALSO IMPLANTED. DURING THE PROCEDURE, ONE OF THE SCREWS BROKE ABOUT THE FIFTH THREAD DOWN. AT THIS TIME, IT IS UNKNOWN WHICH SCREW BROKE. THE SURGEON DECIDED TO LEAVE THE BROKEN FRAGMENT IN THE PATIENT, AS REMOVING IT WOULD CAUSE MORE HARM. ONCE THE PATIENT WAS HEALED, ON (B)(6) 2024, A SECOND PROCEDURE WAS PERFORMED TO REMOVE BOTH PLATES AND EIGHT SCREWS, EXCEPT THE BODY OF THE PREVIOUSLY BROKEN SCREW. THE PART NUMBER FOR THE TROCAR TIP REMAINS UNKNOWN.
Patient problems: Failure of Implant
MAUDE report 20146609 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.