Arthrex® AR-9510-06Recalls & reported problems
Arthrex, Inc. · UNIVERS REVERS RASP/TRIAL STEM - SIZE 6 · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867061668), received between Sep 13, 2018 and Sep 13, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information1
Patient problems
- Bone Fracture(s)1
- Patient Problem/Medical Problem1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 13, 2018Insufficient Device Problem Information
IT WAS REPORTED THAT DURING A REVERSE TOTAL SHOULDER, THE SURGEON SIZED THE HUMERAL STEM AND DECIDED TO USE THE AR-9501-06P THE ARTHREX UNIVERS REVERS HUMERAL STEM SIZE 6. THE OUTER PACKAGE WAS OPENED AND PLACED IN THE STERILE FIELD. THE SURGEON WAS REAMING TO PREP FOR THE CUP TO GO WITH THE STEM, AND AFTER REAMING HE ATTEMPTED TO DO A TRIAL AND REDUCE THE SHOULDER. THE SURGEON FELT THAT HE NEEDED THE TRIAL TO GO DEEPER. THE SURGEON USED A BROACH TO OBTAIN MORE DEPTH, AND WHILE GOING DEEPER WITH THE BROACH THE HUMERUS FRACTURED. AFTER THE HUMERUS FRACTURED, THE SURGEON SIZED UP ON THE BROACH TO GET A BETTER FIT. AN AR-9501-07P, ARTHREX UNIVERS REVERS HUMERAL STEM, SIZE 7 WAS BROUGHT IN TO COMPLETE THE PROCEDURE SUCCESSFULLY. THE REP STATED THAT THE BONE QUALITY OF THE PATIENT WAS SOFT AND FRAGILE. ADDITIONAL INFORMATION HAS BEEN REQUESTED REGARDING THE BROACH. ADDITIONAL INFORMATION RECEIVED ON 09/07/2018: THE REP PROVIDED THE PART AND LOT NUMBER (AR-9510-06 / LOT: 250130401) OF THE BROACH THAT WAS USED DURING THE PROCEDURE THAT CAUSED THE HUMERUS FRACTURE.
Patient problems: Bone Fracture(s); Patient Problem/Medical Problem
MAUDE report 7873300 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page