Arthrex® AR-6435Recalls & reported problems

Arthrex, Inc. · DW OUTFLOW TUBE SET W/REDEUCE TUBING · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00888867118089), received between Oct 3, 2023 and Jun 14, 2024 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Insufficient Flow or Under Infusion” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 2 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 3 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Flow or Under Infusion2
  • Break1
  • Detachment of Device or Device Component1
  • Infusion or Flow Problem1
  • Partial Blockage1
  • Pumping Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Extravasation1
  • Insufficient Information1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 14, 2024Partial Blockage; Partial Blockage

    ON 05/10/2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT AN AR-6435 OUTFLOW SET HAS A CLOG BEHIND THE OUTFLOW CASSETTE. THIS WAS THE END EFFECT, AS THE CLOG ALMOST WRAPPED THE ENTIRE CURVE AND COULD NOT BE RELIEVED. MINOR CASE DELAYS NO PATIENT ISSUES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19537867 ↗
  • MalfunctionJun 8, 2024Break; Break

    ON 05/18/2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS THAT AN AR-6435 OUTFLOW SET IS BROKEN. THIS WAS DISCOVERED DURING AN UNSPECIFIED TIME WITH NO PATIENT EFFECT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19494682 ↗
  • MalfunctionJun 6, 2024Insufficient Flow or Under Infusion; Insufficient Flow or Under Infusion

    ON 09/23/2021 IT WAS REPORTED BY A SALE REPRESENTATIVE VIA SEMS THAT AN AR-6435 DW OUTFLOW TUBING WAS NOT WORKING PROPERLY, OUTFLOW WAS NOT DETECTED. THIS WAS DISCOVERED DURING A PROCEDURE. THERE WAS NO ADDITIONAL INFORMATION PROVIDED.

    Patient problems: Insufficient Information

    MAUDE report 19477322 ↗
  • MalfunctionFeb 28, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    ON 2/8/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA (B)(4) THAT AN AR-6435 DW OUTFLOW TUBE SET TUBING LOOKED LIKE IT WAS STILL ON THE SHAVER. HOWEVER, WHEN THEY WENT TO MOVE IT, THE PIECE OF TUBING THAT CONNECTS TO THE SHAVER WAS ON IT BUT THE WHOLE TUBING WAS COMPLETELY OUT AS IF THE SEALANT CAME APART. THIS WAS DISCOVERED DURING A PROCEDURE WITH NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18799201 ↗
  • MalfunctionFeb 6, 2024Pumping Problem; Pumping Problem

    IT WAS REPORTED THAT DURING A KNEE SURGERY THE PUMP SPEED INCREASES UNCONTROLLABLY. THE CUSTOMER HAS REPORTED THAT THE ISSUE COULD BE SOLVED WITH THE THIRD TUBING SET AND FINISHED THE SURGERY SUCCESSFULLY. THERE WAS NO HARM FOR PATIENT, OPERATOR OR THIRD PARTY REPORTED. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY. UPDATE 04-FEB-2021 DW IT WAS FURTHER REPORTED THAT THE PATIENT WAS ALREADY IN THE SURGERY ROOM BUT THE RELATED PUMP WAS NOT USED ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18653230 ↗
  • MalfunctionOct 3, 2023Insufficient Flow or Under Infusion; Infusion or Flow Problem; Insufficient Flow or Under Infusion; Infusion or Flow Problem

    ON (B)(6) 2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA SEMS-06021994 THAT AN AR-6480 DW ARTHROSCOPY FLUID MANAGEMENT DEVICE HAD AN ISSUE. THE SURGEON NOTICED THE PUMP'S OUTFLOW WAS SLOW TO RESPOND, NOT PULLING FLUID FAST ENOUGH. THE PATIENT WAS NOT AFFECTED. THIS OCCURRED DURING USE IN AN UNSPECIFIED PROCEDURE WITH NO PATIENT HARM. ADDITIONAL INFORMATION HAS BEEN REQUESTED. ON 9/7/2023, THE SALES REPRESENTATIVE PROVIDED THE FOLLOWING INFORMATION VIA EMAIL AND PHONE: THIS OCCURRED DURING A SHOULDER ARTHROSCOPY PROCEDURE ON (B)(6) 2023. AN AR-6411 REDEUCE PUMP TUBING AND AR-6435 DUALWAVE OUTFLOW TUBE SET WITH REDEUCE TUBING SYSTEM WITH UNKNOWN LOT NUMBERS WERE USED. THE PUMP SETTINGS WERE AT 45MMHG, AND THE PUMP WAS NOT KEEPING UP WITH THE PRESSURE. SLIGHT EXTRAVASATION OCCURRED, IT WAS LOCALIZED AND A MANAGEABLE ISSUE. THEY USED A RINSE FUNCTION W/ CLOSED INFLOW PORTAL TO REMOVE THE EXCESS FLUID. THE PUMP WAS USED TO COMPLETE THE PROCEDURE SUCCESSFULLY. THE PATIENT WAS DISCHARGED AFTER THE PROCEDURE AND IS FINE TO DATE, THERE WAS NO HARM REPORTED AND NO CASE DELAY. THE TUBING SETS WERE DISCARDED AFTER THE PROCEDURE.

    Patient problems: Extravasation

    MAUDE report 17862871 ↗