Arthrex® AR-8630-32Recalls & reported problems
Arthrex, Inc. · HEADLESS COMPRES SCRW 3.0X32MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867125827), received between Oct 19, 2020 and Oct 19, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 19, 2020Break
IT WAS REPORTED DURING A FUSION OF THE MTP USING 3.0 SMALL HEADLESS COMPRESSION SCREW, AR-8630-32, THE SCREW HEAD BROKE OFF DURING INSERTION. THE INSERTION WAS DONE BY HAND. SURGEON ATTEMPTED TO REMOVE THE SCREW AND WAS ONLY ABLE TO REMOVE PART OF IT. THE OTHER PIECE WAS LEFT IN THE PATIENT WITHOUT ANY FURTHER INCIDENT. ADDITIONAL INFORMATION PROVIDED 10/7/2020: HALF OF THE SCREW WAS LEFT UN-RETRIEVED FROM THE PATIENT. THE PATIENT'S BONE QUALITY WAS HARD AND WAS PREPPED WITH A K-WIRE, APPROPRIATE SIZE DRILL AND COUNTERSINK, WAS PUT IN BY HAND. THE CASE WAS COMPLETED BY REMOVING ABOUT HALF OF THE BROKEN SCREW, THEN FUSED THE MTP WITH 4.0 CANNULATED SCREW (NOT ARTHREX).
Patient problems: Foreign Body In Patient
MAUDE report 10701283 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page