Arthrex® AR-1788PJ-CPRecalls & reported problems
Arthrex, Inc. · IB Kit, PEEK, w/ CC FT and JumpStart · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867218208), received between Apr 17, 2023 and Apr 17, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 17, 2023Break; Break
HOLF NH 4/17 ON (B)(6) 2023, IT WAS REPORTED BY A FACILITY REPRESENTATIVE VIA SEMS THAT A DRILL BIT FROM AN AR-1788PJ-CP INTERNALBRACE IMPLANT SYSTEM BROKE WITHIN THE PATIENT'S TALUS. FLUOROSCOPIC X-RAYS WERE TAKEN, WHICH DEMONSTRATED COMPLETE INTRAOSSEOUS FRAGMENTATION OF THE TIP OF THE DRILL BIT. UPON DIRECT VISUALIZATION OF THE DRILL BIT, IT WAS NOTED TO BE COMPLETELY INTRAOSSEOUS AT THE TALUS SITE. THE INTERNAL CANNULATION WAS NOT INTACT, SO THE SURGEON COULD NOT REMOVE IT WITH A REVERSE-THREADED HARDWARE REMOVAL INSTRUMENT. THE SURGEON ALSO ELECTED AGAINST PUTTING A TREPHINE OVER THE TOP TO REMOVE IT. IT'S BELIEVED THIS COULD CREATE MORE DAMAGE AND A LARGER HOLE IN THE TALUS WHICH WOULD NOT PROVIDE ANY ADDITIONAL BENEFIT AND MAY POTENTIALLY INCREASE RISK. THIS WAS DISCOVERED DURING A RIGHT ANKLE ANTERIOR TALOFIBULAR LIGAMENT REPAIR WITH INTERNALBRACE AND ARTHROSCOPY WITH DEBRIDEMENT PROCEDURE ON (B)(6) 2023.
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 16751865 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page