Arthrex® AR-9943BL-04Recalls & reported problems
Arthrex, Inc. · Locking Distal Fibula Plate, Ti ,Left,4H · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867255609), received between Aug 17, 2023 and Aug 13, 2025 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem1
- Positioning Failure1
Patient problems
- Hypersensitivity/Allergic reaction1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 13, 2025Positioning Failure; Positioning Failure
ON 07/28/2025, A SALES REPRESENTATIVE REPORTED VIA EMAIL THAT TWO AR-8935CL-14 KREULOCK COMPRESSION SCREW (3.5 MM X 14 MM) FAILED TO ENGAGE WITH THE LOCKING MECHANISM OF AN AR-9943BL-04 LOCKING DISTAL FIBULA PLATE DURING AN ANKLE FRACTURE PROCEDURE ON (B)(6) 2025. DESPITE PROPER DRILLING USING THE DESIGNATED DRILL TOWER, BOTH SCREWS SPUN FREELY WITHIN THE HOLE AND DID NOT LOCK INTO THE PLATE. A 4.0 MM CORTICAL SCREW WAS ULTIMATELY USED TO FILL THE HOLE; HOWEVER, LOCKING WAS NOT ACHIEVED, AND THEY SUSPECT THAT THE ISSUE IS WITH THE LOCKING THREADS ON THE PLATE. ADDITIONAL INFORMATION HAS BEEN REQUESTED ON 08/01/2025.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22793773 ↗InjuryAug 17, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT SURGERY ON (B)(6) 2018 FOR AN OPEN REDUCTION INTERNAL FIXATION OF A LEFT TRIMALLEOLAR ANKLE FRACTURE WITH FIXATION OF THE DISTAL FIBULA FRACTURE, POSTERIOR MALLEOLUS FRACTURE, AND SYNDESMOTIC FIXATION. DURING THE (B)(6) 2018 SURGERY, THE FOLLOWING PRODUCTS WERE USED AND/OR IMPLANTED: AR-8740-52PTS QCKFIX SCRW,TI,CANN ST,CANC.,4.0X 52MM, LOT/SERIAL (B)(6). AR-8925T K-LESS T-ROPE W/DRV, SYN REPR, TI, LOT/SERIAL (B)(6). AR-8933-20 LO-PRO SCRW,TI,3.0MMX 20MMCORT, LOT/SERIAL (B)(6). AR-8933V-12 3.0 X 12MM VAL SCREW, TI, LOT/SERIAL (B)(6). AR-8933V-14 3.0 X 14MM VAL SCREW, TI, LOT/SERIAL (B)(6). AR-8933V-16 3.0 X 16MM VAL SCREW, TI, LOT/SERIAL (B)(6). AR-8933V-18 3.0 X 18MM VAL SCREW, TI, LOT/SERIAL (B)(6). AR-8933V-20 3.0 X 20MM VAL SCREW, TI, LOT/SERIAL (B)(6). AR-8935-12 LO-PRO SCRW,TI,3.5MMX 12MM, LOT/SERIAL (B)(6). AR-8935-14 LO-PRO SCRW,TI,3.5MMX 14MM, LOT/SERIAL (B)(6). AR-8935-14 LO-PRO SCRW,TI,3.5MMX 14MM, LOT/SERIAL (B)(6). AR-8935-26 LO-PRO SCRW,TI,3.5MMX 26MM, LOT/SERIAL (B)(6). AR-8943-01 GUIDE WIRE, TROCAR TIP, 1.35 MM, LOT/SERIAL (B)(6). AR-8943-02 DRILL BIT, CANNULATED, 2.6MM, LOT/SERIAL (B)(6). AR-8943-16 2.0MM DRILL BIT, CALIBR
Patient problems: Hypersensitivity/Allergic reaction
MAUDE report 17563229 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page