Arthrex® AR-9301-45CPCRecalls & reported problems
Arthrex, Inc. · ECLIPSE TRUNION 45MM, SLOTTED, TPS CaP · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00888867276154), received between Aug 11, 2021 and Mar 12, 2025 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem1
- Positioning Failure1
- Positioning Problem1
Patient problems
- Failure of Implant1
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 12, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
ON 2/17/2025, A CLINDEX NOTIFICATION WAS RECEIVED INDICATING THAT A PATIENT LISTED ON THE SHOULDER ARTHROPLASTY REGISTRY SUFFERED A RUPTURED SUBSCAPULARIS DUE TO A TRAUMATIC FALL. THE PATIENT UNDERWENT REVISION SURGERY OF THE ANATOMIC SHOULDER REPLACEMENT TO A REVERSE SHOULDER ARTHROPLASTY ON (B)(6) 2023. THE EVENT WAS INDICATED AS UNRELATED TO THE ECLIPSE SYSTEM IMPLANTED ON (B)(6) 2023. ADDITIONAL INFORMATION RECEIVED ON 2/27/2025: ON (B)(6) 2023, THE PATIENT UNDERWENT REVISION SURGERY TO HAVE AN AR-9301-45CPC ARTHREX ECLIPSE TRUNION, AN AR-9106-02 ARTHREX UNIVERS VAULTLOCK GLENOID, AN AR-9301-03 ARTHREX ECLIPSE CAGE SCREW LARGE, AND AN AR-9345-17 ARTHREX ECLIPSE HUMERAL HEAD REMOVED. AFTER THE SURGERY, THE PATIENT IS DOING WELL WITH AN EIGHTY-FIVE TO NINETY PERCENT IMPROVEMENT IN SYMPTOMS.
Patient problems: Failure of Implant
MAUDE report 21586152 ↗MalfunctionJan 13, 2025Positioning Failure; Positioning Failure
ON 12/16/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-9400-SBK ECLIPSE SPEEDSCAP IMPLANT SYSTEM DID NOT GET SUFFICIENT FIXATION WITH THE ECLIPSE TRUNION AND CAGE SCREW. THE CASE WAS COMPLETED USING A LONG STEM. THIS WAS DISCOVERED DURING AN ANATOMIC TOTAL SHOULDER PROCEDURE ON (B)(6) 2024. ADDITIONAL INFORMATION RECEIVED ON 12/30/2024: THE PART NUMBERS AR-9301-02 AND CAGE SCREW AND AR-9301-45CPC ARTHREX ECLIPSE TRUNION WERE PROVIDED. ADDITIONALLY, THE SALES REPRESENTATIVE REPORTED THAT ANOTHER AR-9400-SBK ECLIPSE SPEEDSCAP IMPLANT SYSTEM FROM A DIFFERENT LOT NUMBER AND AN AR-9301-01 ARTHREX ECLIPSE CAGE SCREW WAS ATTEMPTED TO BE USED AS WELL BUT STILL COULD NOT GET SUFFICIENT FIXATION. THE CASE WAS COMPLETED USING AN AR-9100-05M UNIVERS APEX OPTIFIT HUMERAL STEM. THE CASE WAS DELAYED BETWEEN THIRTY TO FORTY MINUTES; HOWEVER, ADDITIONAL ANESTHESIA WAS NOT NEEDED.
Patient problems: Insufficient Information
MAUDE report 21136741 ↗InjuryAug 11, 2021Positioning Problem
IT WAS REPORTED DURING A TOTAL SHOULDER ARTHROPLASTY, WHEN THE SURGEON WAS GOING TO USE THE ECLIPSE, IT WAS NOT SITTING WELL AND THE SURGEON DIVERTED TO AN UNIVERS HEAD AND APEX STEM. NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12306237 ↗
FDA clearance and classification
The FDA regulates product code QHQ (total shoulder arthroplasty system) under 21 CFR 888.3660 as a Class II device. 21 CFR 888.3660 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the Arthrex® AR-9301-45CPC
Has the Arthrex® AR-9301-45CPC been recalled?
No FDA recall record in our data names this exact device identifier (DI 00888867276154), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Arthrex® AR-9301-45CPC?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Aug 11, 2021 and Mar 12, 2025. In those reports, the most common specific device problems are “Patient Device Interaction Problem” (1), “Positioning Failure” (1) and “Positioning Problem” (1); the most common patient problem is “Failure of Implant” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Arthrex® AR-9301-45CPC?
None of the reports are classified as deaths, 2 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Arthrex® AR-9301-45CPC MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the Arthrex® AR-9301-45CPC, and is it still sold?
The FDA's device database lists Arthrex, Inc. as the company responsible for it (brand Arthrex®, model AR-9301-45CPC). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Total shoulder arthroplasty system devices
- Arthrex® AR-9301-03Arthrex, Inc. · Total shoulder arthroplasty system12 reports
- Arthrex® AR-9349-18Arthrex, Inc. · Total shoulder arthroplasty system9 reports
- Arthrex® AR-9301-01Arthrex, Inc. · Total shoulder arthroplasty system9 reports
- Arthrex® AR-9347-18Arthrex, Inc. · Total shoulder arthroplasty system7 reports
- Arthrex® AR-9343-16Arthrex, Inc. · Total shoulder arthroplasty system7 reports
- Arthrex® AR-9301-02Arthrex, Inc. · Total shoulder arthroplasty system6 reports
- Arthrex® AR-9345-17Arthrex, Inc. · Total shoulder arthroplasty system6 reports
- Arthrex® AR-9341-16Arthrex, Inc. · Total shoulder arthroplasty system5 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page