Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867276178), received between Sep 29, 2026 and Sep 29, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem1
Patient problems
- Device Overstimulation of Tissue1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 29, 2026Patient Device Interaction Problem
On 10/10/2024, a Clindex notification was received indicating that a patient listed on the Shoulder Arthroplasty Registry suffered a displaced lesser tuberosity osteotomy and subscapularis tendon tear. On (b)(6) 2024, the patient reported continuous pain after having experienced a jerk on the arm while walking the dog. The patient was treated with steroid injections. In (b)(6) 2024, a CT scan showed a displaced lesser tuberosity osteotomy and subscapularis tendon tear. The patient has been scheduled for an Arthroscopic subscapularis tendon tear repair procedure in (b)(6) 2024. This event was initially indicated as unrelated to the Eclipse devices implanted on (b)(6) 2024.\\Additional information received on 10/17/2024:\During the original surgery, an AR-9106-03 Arthrex Univers VaultLock Glenoid, an AR-9349-18 Arthrex ECLIPSE Humeral Head, an AR-9301-49CPC Arthrex ECLIPSE Trunion, and an AR-9301-02 Arthrex ECLIPSE Cage Screw were implanted. After the patient received steroid injections, the patient's symptoms were persistent despite the injection, therefore the CT was ordered for further evaluation. Upon CT review, lesser tuberosity osteotomy displacement was seen, and it was determ
Patient problems: Device Overstimulation of Tissue
MAUDE report 50938383 ↗
FDA clearance and classification
The FDA regulates product code QHQ (total shoulder arthroplasty system) under 21 CFR 888.3660 as a Class II device. 21 CFR 888.3660 ↗
Devices of this type normally need 510(k) clearance before sale.
Common questions about the Arthrex® AR-9301-49CPC
Has the Arthrex® AR-9301-49CPC been recalled?
No FDA recall record in our data names this exact device identifier (DI 00888867276178), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Arthrex® AR-9301-49CPC?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 29, 2026. That report lists device problem “Patient Device Interaction Problem” (1); patient problem “Device Overstimulation of Tissue” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Arthrex® AR-9301-49CPC?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Arthrex® AR-9301-49CPC MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the Arthrex® AR-9301-49CPC, and is it still sold?
The FDA's device database lists Arthrex, Inc. as the company responsible for it (brand Arthrex®, model AR-9301-49CPC). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Total shoulder arthroplasty system devices
- Arthrex® AR-9301-03Arthrex, Inc. · Total shoulder arthroplasty system12 reports
- Arthrex® AR-9349-18Arthrex, Inc. · Total shoulder arthroplasty system9 reports
- Arthrex® AR-9301-01Arthrex, Inc. · Total shoulder arthroplasty system9 reports
- Arthrex® AR-9347-18Arthrex, Inc. · Total shoulder arthroplasty system7 reports
- Arthrex® AR-9343-16Arthrex, Inc. · Total shoulder arthroplasty system7 reports
- Arthrex® AR-9301-02Arthrex, Inc. · Total shoulder arthroplasty system6 reports
- Arthrex® AR-9345-17Arthrex, Inc. · Total shoulder arthroplasty system6 reports
- Arthrex® AR-9341-16Arthrex, Inc. · Total shoulder arthroplasty system5 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page