Arthrex® AR-8730-46HSRecalls & reported problems
Arthrex, Inc. · COMPR FT SCRW,3.5 MINI, 46mm · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867304017), received between Jan 31, 2022 and Dec 27, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
Patient problems
- Foreign Body In Patient1
- Unspecified Tissue Injury1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 27, 2023Break; Break
IT WAS REPORTED THAT DURING A SURGERY THE SCREW BROKE WHEN THE SURGEON TRIED TO REMOVE IT FROM THE PATIENT. THE BROKEN SCREW COULD NOT BE RETRIEVED FROM THE PATIENT. THE SURGERY WAS FINISHED SUCCESSFULLY WITH THE SAME DEVICE. IT WAS NOT NECESSARY TO SWITCH THE SURGICAL TECHNIQUE OR DO A SECOND SURGERY.
Patient problems: Foreign Body In Patient
MAUDE report 18406050 ↗MalfunctionJan 31, 2022Break
IT WAS REPORTED THAT DURING A METAL REMOVAL OF TWO SCREWS AR-8730-42HS (LOT 10327710) AND AR-8730-46HS (LOT 10327712) THE HEAD OF THE SCREW AR-8730-46HS (LOT 10327712) BROKE DURING UNSCREWING WITH THE NORMAL SCREWDRIVER FOR THE DEVICE. THE DEVICE AR-8737-62 (LOT 1391931) WAS THEN USED TO GRASP THE BROKEN SCREW AND ALSO BROKE. THE BROKEN SCREW HAD TO BE CHISELED FREE TO REMOVE IT, WHICH CAUSED MUCH DAMAGE TO THE BONE. THE DURATION OF THE SURGERY WAS PROLONGED BY APPROXIMATELY 45 MINUTES DUE TO THE FAILURES. NO BROKEN PARTS REMAINED INSIDE THE PATIENT. THE SURGERY WAS FINISHED SUCCESSFULLY AND IT WAS NOT NECESSARY TO DO A SECOND SURGERY.
Patient problems: Unspecified Tissue Injury
MAUDE report 13396606 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page