Arthrex® AR-5875-2Recalls & reported problems
Arthrex, Inc. · Knee Capsule Repair System w/GAP guide · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00888867307513), received between Feb 1, 2021 and Oct 17, 2023 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break4
- Defective Device1
- Entrapment of Device1
Patient problems
- Insufficient Information2
- No Clinical Signs, Symptoms or Conditions2
- Foreign Body In Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 17, 2023Defective Device; Defective Device
ON (B)(6) 2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT AN AR-5875-2 KNEE CAPSULE REPAIR IMPLANT SYSTEM WITH GAP DRILL GUIDE FAILED DURING A PROCEDURE. ADDITIONAL INFORMATION REQUESTED.
Patient problems: Insufficient Information
MAUDE report 17951507 ↗MalfunctionAug 11, 2023Break; Break
ON 07/13/2023, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA PHONE THAT AN AR-5875-2 KNEE CAPSULE REPAIR IMPLANT SYSTEM, PIECE OF GUIDE BROKE OFF DURING INSERTION OF THE IMPLANT. THIS WAS DISCOVERED DURING A CASE WITH NO PATIENT EFFECT. ALL FRAGMENTS REMOVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17513010 ↗MalfunctionNov 11, 2021Break; Entrapment of Device
ON (B)(6) 2021, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT (2) AR-5875-2 DRILL GUIDES SNAPPED. THIS OCCURRED ON (B)(6) 2021 DURING A MENSICO-CAPSULAR REPAIR IN CONJUNCTION WITH A MENISCAL ROOT REPAIR. AFTER THE SURGEON PERFORMED THE ROOT PORTION OF THE PROCEDURE, HE HAD PLACED THE GUIDEWIRES AND BEGAN DRILLING FOR HIS SUTURE TAKS. UPON INSERTION OF THE SECOND ANCHOR THE GAP GUIDE SNAPPED, CAUSING THE TEAM TO SKIVE WITH THE ANCHOR. A SECOND KIT WAS OPENED UP FOR THE GUIDE, BUT UPON INSERTING THE ANCHOR, THE GAP GUIDE BROKE WITH THE ANCHOR STAYING IN THE BONE. FOR THE THIRD ANCHOR THE SURGEON CHOSE TO FREEHAND THE DRILL INSTEAD OF OPENING ANOTHER KIT.
Patient problems: Foreign Body In Patient
MAUDE report 12793537 ↗MalfunctionMay 24, 2021Break
IT WAS REPORTED DURING A CAPSULAR REPAIR OF THE KNEE, THE PURPLE HANDLED GAP GUIDE BROKE UNDER A SMALL AMOUNT OF TENSIONING/LEVERING. THE SHORTER GUIDE COMPONENT FOR THE WIRES SNAPPED OFF THE LARGER DRILL GUIDE. ALL FRAGMENTS WERE RETRIEVED AND THE CASE WAS COMPLETED.
Patient problems: Insufficient Information
MAUDE report 11871696 ↗MalfunctionFeb 1, 2021Break
IT WAS REPORTED THAT DURING A KNEE CAPSULE REPAIR PROCEDURE THE SURGEON WAS USING AR-5875-2, ARTHREX KNEE CAPSULE REPAIR SYSTEM (LOT 12170195). DURING USE THE GUIDE FROM THE KIT BROKE. SURGEON THEN TRIED FREE-HANDING THE GUIDE'S POSITION AND BOTH ANCHORS PULLED OUT. ADDITIONAL INFORMATION OBTAINED 01/20/2021: DATE OF PROCEDURE WAS (B)(6) 2021. ALL COMPONENTS/PIECES OF THE AR-5875-2 WERE FULLY RETRIEVED AND NOTHING WAS LEFT IN THE PATIENT. THE SURGEON THEN USED SUTURE TO COMPLETE HIS REPAIR. ALL COMPONENTS OF THE COMPLAINT DEVICE WERE DISCARDED AT THE TIME OF PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11258741 ↗
Other Fastener, fixation, biodegradable, soft tissue devices
- GRYPHON ORTHOCORD 210813Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE712 reports
- HEALIX ADVANCE 222330Depuy Mitek, LLC · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE1 recall607 reports
- HEALIX ADVANCE ORTHOCORD 222295Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE640 reports
- HEALICOIL 72205137Smith & Nephew, Inc. · Fastener, fixation, biodegradable, soft tissue427 reports
- HEALIX ADVANCE ORTHOCORD 222296Medos International Sàrl · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE320 reports
- TWINFIX 72202597Smith & Nephew, Inc. · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE288 reports
- Arthrex® AR-2324BCCArthrex, Inc. · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE254 reports
- HEALIX ADVANCE 222331Depuy Mitek, LLC · FASTENER, FIXATION, BIODEGRADABLE, SOFT TISSUE1 recall196 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page