Arthrex® AR-8835CL-36Recalls & reported problems
Arthrex, Inc. · KreuLock Compression Screw, SS, 3.5x36mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867323476), received between Feb 13, 2025 and Feb 13, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 13, 2025Break; Break
ON 1/27/2025, AN FDA MEDWATCH NOTIFICATION WAS RECEIVED VIA EMAIL. A FACILITY REPRESENTATIVE REPORTED THAT A PLATE AND MULTIPLE SCREWS WERE IMPLANTED IN A PATIENT. TWO ARTHREX SCREWS BROKE DURING IMPLANTATION. ONE SCREW WAS SUCCESSFULLY REMOVED, AND THE OTHER SCREW WAS PARTIALLY REMOVED. THE PARTIAL SCREW WAS LEFT IN PLACE. THE PROCEDURE WAS PERFORMED UNDER FLUOROSCOPY, AND THE PARTIAL SCREW WAS OBSERVED BY THE OPERATING ROOM STAFF AND THE SURGEON. THIS WAS DISCOVERED DURING AN ANKLE FRACTURE PROCEDURE ON (B)(6) 2025. NO FURTHER INFORMATION WAS PROVIDED. ADDITIONAL INFORMATION WAS PROVIDED ON 2/5/2025: THE FACILITY REPRESENTATIVE PROVIDED PART AR-8835CL-32 KREULOCK COMPRESSION SCREW AS THE SCREW THAT WAS REMOVED ENTIRELY. THE AR-8835CL-36 KREULOCK COMPRESSION SCREW WAS PARTIALLY REMOVED. THE AR-8963ML-10 MEDIAL DISTAL TIBIA PLATE REMAINED IN THE PATIENT AND SUFFERED NO DAMAGE OR MALFUNCTION. THE CASE WAS COMPLETED USING THE SAME PLATE WITH NEW SCREWS. THE CASE WAS NOT DELAYED, AND ADDITIONAL ANESTHESIA WAS NOT NEEDED.
Patient problems: Foreign Body In Patient
MAUDE report 21375617 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page