Arthrex® AR-8724VCL-16Recalls & reported problems
Arthrex, Inc. · VAL KreuLock Screw, Ti, 2.4x16 · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867323957), received between Sep 9, 2025 and Sep 9, 2025 — classified as 2 injuries.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem2
Patient problems
- Numbness2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 9, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
ON (B)(6) 2025, A CLINDEX NOTIFICATION WAS RECEIVED INDICATING THAT A PATIENT ENROLLED IN THE HAND AND WRIST REGISTRY HAD DEVELOPED CARPAL TUNNEL SYNDROME. THE PATIENT HAD PREVIOUSLY PRESENTED FOR FOLLOW-UP ON (B)(6) 2025, REPORTING PROGRESSIVE NUMBNESS IN THE THUMB, INDEX, AND LONG FINGERS FOLLOWING SURGERY. ULTRASOUND EVALUATION OF THE RIGHT CARPAL TUNNEL REVEALED FINDINGS CONSISTENT WITH CARPAL TUNNEL SYNDROME. TO ALLEVIATE SYMPTOMS, THE PATIENT UNDERWENT RIGHT CARPAL TUNNEL RELEASE SURGERY ON (B)(6) 2025. THIS EVENT WAS DETERMINED TO BE RELATED TO THE KREULOCK SCREW UTILIZED DURING THE DISTAL RADIUS FRACTURE FIXATION PROCEDURE PERFORMED ON (B)(6) 2025. ADDITIONAL INFORMATION WAS RECEIVED ON 8/20/2025: DURING THE PROCEDURE ON (B)(6) 2025, THE PATIENT WAS IMPLANTED WITH AN AR-8724VCL-18 VAL KREULOCK SCREW, AN AR-8724VCL-16 VAL KREULOCK SCREW, AN AR-8724VCL-14 VAL KREULOCK SCREW, AN AR-8935-12 LOW PROFILE SCREW, AND AN AR-8916VNR-03 VOLAR DISTAL RADIUS PLATE. NO ARTHREX PRODUCTS WERE EXPLANTED OR IMPLANTED DURING THE RIGHT CARPAL TUNNEL RELEASE SURGERY ON (B)(6) 2025. THE SURGEON CONFIRMED THAT THE PATIENT'S CARPAL TUNNEL SYNDROME IS NOT RELATED TO THE ARTHREX PRODUCTS, AS MANY PA
Patient problems: Numbness
MAUDE report 23005596 ↗InjurySep 9, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
ON (B)(6) 2025, A CLINDEX NOTIFICATION WAS RECEIVED INDICATING THAT A PATIENT ENROLLED IN THE HAND AND WRIST REGISTRY HAD DEVELOPED CARPAL TUNNEL SYNDROME. THE PATIENT HAD PREVIOUSLY PRESENTED FOR FOLLOW-UP ON (B)(6) 2025, REPORTING PROGRESSIVE NUMBNESS IN THE THUMB, INDEX, AND LONG FINGERS FOLLOWING SURGERY. ULTRASOUND EVALUATION OF THE RIGHT CARPAL TUNNEL REVEALED FINDINGS CONSISTENT WITH CARPAL TUNNEL SYNDROME. TO ALLEVIATE SYMPTOMS, THE PATIENT UNDERWENT RIGHT CARPAL TUNNEL RELEASE SURGERY ON (B)(6) 2025. THIS EVENT WAS DETERMINED TO BE RELATED TO THE KREULOCK SCREW UTILIZED DURING THE DISTAL RADIUS FRACTURE FIXATION PROCEDURE PERFORMED ON (B)(6) 2025. ADDITIONAL INFORMATION WAS RECEIVED ON (B)(6) 2025: DURING THE PROCEDURE ON (B)(6) 2025, THE PATIENT WAS IMPLANTED WITH AN AR-8724VCL-18 VAL KREULOCK SCREW, AN AR-8724VCL-16 VAL KREULOCK SCREW, AN AR-8724VCL-14 VAL KREULOCK SCREW, AN AR-8935-12 LOW PROFILE SCREW, AND AN AR-8916VNR-03 VOLAR DISTAL RADIUS PLATE. NO ARTHREX PRODUCTS WERE EXPLANTED OR IMPLANTED DURING THE RIGHT CARPAL TUNNEL RELEASE SURGERY ON (B)(6) 2025. THE SURGEON CONFIRMED THAT THE PATIENT'S CARPAL TUNNEL SYNDROME IS NOT RELATED TO THE ARTHREX PRODUCTS, AS MANY
Patient problems: Numbness
MAUDE report 23005578 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page