Arthrex® AR-8771-0427XRecalls & reported problems
Arthrex, Inc. · DynaNite Comp Plate, 4-Hole Square, 27mm · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867339903), received between Oct 11, 2021 and Jun 18, 2024 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Failure of Implant1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 18, 2024Break; Break
IT WAS REPORTED THE PATIENT UNDERWENT A PRIMARY SURGERY ON (B)(6) 2020. THE FOLLOWING ARTHREX PRODUCT WAS IMPLANTED DURING THE PRIMARY SURGERY. AR-8771-0230S (LOT: 10722395) / QTY. 1, AR-8771-0427X (LOT: 10722415) / QTY. 1, AR-8719MXDS-1818 (LOT: 0051101455) / QTY. 1. THE SURGEON PUT THE PATIENT INTO BOOT DURING WEEK 5/6. TO THE SURGEONS KNOWLEDGE THE PATIENT WAS COMPLIANT. IT WAS REPORTED THAT THERE WAS ONE DAY THE PATIENT WAS DOING HOUSE CHORES WHILE IN THE BOOT AND FELT PAIN IN THEIR FOOT AFTER STANDING FOR A LONG PERIOD OF TIME BUT CLAIMED TO HAVE NO INJURY. DURING WEEK 8/9 PATIENT CAME INTO CLINIC AND SURGEON NOTICED A CRACK IN THE AR-8771-0230S. THEN WEEK 12 CAME AROUND, AND THE SECOND PLATE AR-8771-0427X HAD BROKEN. STAPLE WAS INTACT THROUGHOUT THIS TIME FRAME. ON (B)(6) 2021, THE PATIENT CAME BACK INTO CLINIC AND X-RAY SHOWS THAT THE PROXIMAL STAPLE ARM OF AR-8719MXDS-1818 WAS BROKEN AS WELL. AS OF NOW PATIENTS PAIN LEVEL IS OKAY, AND THE SURGEON PLANS TO REMOVE HARDWARE AT ONE YEAR POST-OP. SEE SOURCE DATA AND X-RAY IMAGE ATTACHED. ADDITIONAL INFORMATION RECEIVED ON 5/14/2021: THE REP REPORTED THE ORIGINAL PROCEDURE TYPE WAS A MIDFOOT FUSION. AT THIS TIME, THE REVISION SUR
Patient problems: Failure of Implant
MAUDE report 19558615 ↗InjuryOct 11, 2021Break
ON (B)(6) 2021, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA E-MAIL THAT AN AR-8771-0422X DYNANITE COMP PLATE AND AN AR-8771-0427X DYNANITE COMP PLATE BROKE POST-OPERATIVE. THE DATE OF THE PRIMARY PROCEDURE WAS (B)(6) 2020 FOR A TN AND CC FUSION. THIS PROCEDURE TOOK PLACE AT ST. CLOUD HOSPITAL, ARTHREX ACCOUNT# (B)(4). DATE OF REVISION IS UNKNOWN.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 12609029 ↗
Other Plate, fixation, bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page