Skip to content

Arthrex® AR-2326PSLC-1Recalls & reported problems

Arthrex, Inc. · 3.9MM PEEK SWIVELOCK · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867341982), received between Sep 26, 2022 and Sep 26, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 26, 2022Break

    ON (B)(6) 2022, IT WAS REPORTED BY VIA EMAIL THAT WHILE USING A AR-2326PSLC-1, 3.9MM PEEK SWIVELOCK, THE SURGEON WAS SHUTTLING THE ANCHOR TO THE HOLE AND THE EYELET BROKE OFF. THIS WAS DISCOVERED DURING USE AND THE PATIENT WAS INVOLVE. TO COMPLETE THE PROCEDURE, ANOTHER ANCHOR HAS BEEN USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15484226 ↗

Other Fastener, fixation, biodegradable, soft tissue devices

All Fastener, fixation, biodegradable, soft tissue devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page