Arthrex® AR-3610CTC-2Recalls & reported problems
Arthrex, Inc. · Tight Curved Spear, FiberTak, Reusable · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867354296), received between Feb 21, 2025 and Mar 18, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Physical Resistance/Sticking2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 18, 2026Physical Resistance/Sticking
ON 26-FEB-2026, A SALES REPRESENTATIVE REPORTED VIA (B)(4) THAT THE AR-3610CTC-2 1.8 KNOTLESS FIBERTAK 30-DEGREE CURVED GUIDE WAS COMPROMISED DURING INSERTION OF A 1.8 KNOTLESS FIBERTAK ANCHOR DURING A SHOULDER INSTABILITY PROCEDURE. GUIDE WAS PLACED INTERARTICULAR, A 1.8MM FLEXIBLE DRILL WAS PLACED DOWN THE GUIDE. THE DRILL WAS USED AND REMOVED, A 1.8 KNOTLESS FIBERTAK ANCHOR WAS PLACED DOWN GUIDE AND INSERTED SUCCESSFULLY, THE SURGEON WENT TO REMOVE THE ANCHOR DRIVER, AND IT WAS COMPLETELY STUCK WITHIN THE GUIDE - THE STABILITY SLEEVE WAS JAMMED IN THE PROXIMAL END OF THE GUIDE WITH NO ABILITY TO REMOVE THE ANCHOR DRIVER. SURGEON CUT THE ANCHOR OUT AND WAS ABLE TO REMOVE THE GUIDE AND ANCHOR DRIVER WITH ANCHOR AND SUTURES STILL HOUSED WITHIN. THE SURGEON USED A NEW ANCHOR AND GUIDE TO INSERT AND COMPLETE THE PROCEDURE. THIS ISSUE WAS DISCOVERED DURING A CASE WITH NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24626900 ↗MalfunctionFeb 21, 2025Physical Resistance/Sticking; Physical Resistance/Sticking
ON 01/27/2025, IT WAS REPORTED BY A ARTHREX SUBSIDIARY EMPLOYEE VIA (B)(6) THAT AN AR-3610CTC-2 FIBNERTAK SPEAR AND AN AR-3600 FIBERTAK ANCHOR BECAME STUCK IN THE DRILL GUIDE WHEN THE SURGEON WENT TO INSERT. THIS OCCURRED DURING USE IN AN ARCR CASE WITH NO PATIENT HARM. THIS CASE WAS COMPLETED BY USING ANOTHER PRODUCT OF SAME PRODUCT NUMBER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21436540 ↗
Other Orthopedic manual surgical instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page