Arthrex® AR-8735BV-38Recalls & reported problems

Arthrex, Inc. · 3.5x38mm Beveled FT Screw · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00888867360822), received between Dec 3, 2024 and Sep 4, 2025 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Positioning Failure1

Patient problems

  • Foreign Body In Patient1
  • Insufficient Information1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 4, 2025Positioning Failure; Positioning Failure

    ON (B)(6) 2025, A FACILITY REPRESENTATIVE REPORTED VIA EMAIL THAT AN AR-8735BV-38 BEVELED FT SCREW WAS FOUND TO BE PROMINENTLY POSITIONED IN THE MCP JOINT SPACE. SURGICAL REMOVAL IS PLANNED FOR THE END OF (B)(6). THIS ISSUE WAS IDENTIFIED POST-IMPLEMENTATION, WITH NO ADDITIONAL DETAILS PROVIDED. ADDITIONAL INFORMATION WAS RECEIVED ON 08/26/2025: THE PATIENT UNDERWENT OPEN REDUCTION AND INTERNAL FIXATION WITH AN INTRAMEDULLARY SCREW FOR A RIGHT FIFTH METACARPAL NECK FRACTURE WITH SIGNIFICANT DISPLACEMENT ON (B)(6) 2025. THE ARTHREX PRODUCT IMPLANTED DURING THE PROCEDURE WAS THE AR-8735BV-38 BEVELED FT SCREW (3.5 MM X 38 MM). DURING THE PROCEDURE, THE SURGEON NOTED THAT THE SCREW HAD BEEN STRIPPED AND SUBSEQUENTLY BURRED DOWN THE PROMINENT PORTION. FINAL INTRAOPERATIVE X-RAYS CONFIRMED THAT THE SCREW WAS BURIED BENEATH THE ARTICULAR CARTILAGE. THE SURGEON THEN ASSESSED THE SMALL FINGER MCP JOINT THROUGH ITS RANGE OF MOTION. THE FRACTURE WAS STABILIZED, AND THERE WAS NO EVIDENCE OF IMPINGEMENT FROM THE IMPLANT. SCREW PROMINENCE WAS FIRST IDENTIFIED VIA X-RAY IMAGING AT THE PATIENT'S ROUTINE FOUR-WEEK FOLLOW-UP VISIT ON (B)(6) 2025 (SEE ATTACHMENT). DURING THIS APPOINTMENT, THE PATIENT

    Patient problems: Foreign Body In Patient

    MAUDE report 22962444 ↗
  • MalfunctionDec 3, 2024Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth

    ADDITIONAL INFORMATION RECEIVED ON 12/16/2024: THE TWO PROTRUDING SCREWS ARE IN THE THIRD AND FOURTH METACARPALS. A REVISION SURGERY HAS BEEN SCHEDULED FOR (B)(6) 2025.

    Patient problems: Insufficient Information

    MAUDE report 20835329 ↗

Other Screw, fixation, bone devices

All Screw, fixation, bone devices →