Arthrex® AR-8735BV-50Recalls & reported problems

Arthrex, Inc. · 3.5x50mm Beveled FT Screw · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867360952), received between Mar 20, 2026 and Mar 20, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Damaged by Another Device1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 20, 2026Device Damaged by Another Device

    ON 02-MAR-2026, A FACILITY REPRESENTATIVE REPORTED VIA (B)(4) THAT AN AR-8741-40 T10 BEVELED HEXALOBE DRIVER SHAFT BROKE OFF INTO THE HEAD OF THE SCREW WHEN INSERTING INTO PATIENT DURING A METACARPAL FX PROCEDURE. THE BROKEN PIECE WAS RETRIEVED FROM THE PATIENT, AND THE CASE WAS COMPLETED SUCCESSFULLY. ADDITIONAL INFORMATION WAS RECEIVED ON 04-MAR-2026. THE REP ADVISED THAT THE SURGEON USED A HANDLE (AR-8700RH) ATTACHED TO THE DRIVER SHAFT (AR-8741-40) TO INSERT THE SCREW BY HAND. THEY STATED THE SURGEON USED A 1.4MM GUIDE WIRE (AR-8741-14), AS WELL AS A 2.9MM DRILL BIT (AR-8741-25) TO PREP THE BONE FOR THE INSERTION OF THE SCREW. THE SURGEON WAS NOT ABLE TO USE THE DRIVER SHAFT (AR-8741-40) TO REMOVE THE SCREW SINCE THE DRIVER SHAFT BROKE OFF INTO THE HEAD OF THE SCREW (AR-8735BV-50). THEY WERE ABLE TO USE INSTRUMENTS THE HOSPITAL OWNED TO RETRIEVE THE REMAINING PIECES OF THE DRIVER SHAFT OUT OF THE HEAD OF THE SCREW. THEY THEN USED A DIFFERENT DRIVER SHAFT TO REMOVE THE SCREW (AR-8735BV-50), THEY RE-DRILLED WITH AN AR-8741-25, AND INSERTED AN AR-8735BV-48, WHICH WAS IMPLANTED USING A DIFFERENT DRIVER SHAFT. THE SURGEON USED THE 3.5MM BEVELED SCREWS, IMPLANTED/EXPLANTED AR-8735BV-

    Patient problems: Insufficient Information

    MAUDE report 24650155 ↗

Other Screw, fixation, bone devices