Arthrex® AR-2600SBS-11Recalls & reported problems

Arthrex, Inc. · TKL SPDBRG IMP SYS W/ BC SWVLK & NDL · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00888867369665), received between Oct 10, 2024 and Oct 10, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 10, 2024Break; Break

    ON 10/1/024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA PHONE THAT ONE OF THE BLUE SWIVELOCK ANCHOR FROM AN AR-2600SBS-11 KNOTLESS SPEEDBRIDGE IMPLANT SYSTEM BROKE DURING INSERTION. THE FRAGMENTS WERE NOT REMOVED. THE CASE WAS COMPLETED USING THE REST OF THE KNOTLESS SPEEDBRIDGE KIT AND AN INDIVIDUAL ANCHOR. THIS WAS DISCOVERED DURING AN RCR PROCEDURE ON (B)(6) 2024. THE CASE WAS DELAYED MORE THAN FIFTEEN MINUTES WITH ADDITIONAL ANESTHESIA. ADDITIONAL INFORMATION RECEIVED ON 10/8/2024: THE SURGEON USED A MALLET LIGHTLY TO IMPACT THE ANCHOR. AFTER THE ANCHOR BROKE, A SNAP WAS HEARD, AS IF THE SUTURES HAD BROKEN INSIDE THE EYELET. THE SUTURES WERE JAMMED IN THE SWIVELOCK INSERTER AND NO LONGER SLIDING. THE ANCHOR REMAINS IN THE PATIENT.

    Patient problems: Foreign Body In Patient

    MAUDE report 20418327 ↗

Other Fastener, fixation, biodegradable, soft tissue devices