NCB® 02.03263.009Recalls & reported problems
Zimmer GmbH · NCB PP PROX FEM PLATE, R, 9H, L. 245MM · Class 2
All models of NCB (78)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889024297456), received between Mar 24, 2021 and Mar 24, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K100111); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fracture1
- Material Integrity Problem1
Patient problems
- Failure of Implant1
- Fall1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 24, 2021Fracture; Material Integrity Problem; Fracture; Material Integrity Problem
NO CHANGE TO PREVIOUSLY REPORTED EVENT.
Patient problems: Failure of Implant; Fall
MAUDE report 11561026 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K100111. One submission often covers many models, so check the product and lot details in each record.
- Z-0329-2020 · Oct 10, 2019 · TerminatedVarious temporary devices used during the implantation of the device system: bone fixation plates and screws, drill bits, manual surgical instruments for general use. Item Nos. 020
- Z-0304-2020 · Oct 10, 2019 · TerminatedNCB PERIPROSTHETIC, "NCB PP PROX FEM PLATE", Various sizes, Item Nos. 0202263009 0202263012 0202263015 0202263018 0202263021 0202263109 0202263112 0202263115 0202263118 0202263121
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page