A.T.S.® Personalized Pressure® 60-2200-101-00Recalls & reported problems

Zimmer Orthopaedic Surgical Products, Inc. · Class 1

All models of A.T.S. Personalized Pressure (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00889024376540), received between Oct 27, 2022 and Aug 28, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Measurement System Incompatibility” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Measurement System Incompatibility3
  • Deflation Problem1
  • Noise, Audible1
  • Output Problem1
  • Use of Incorrect Control/Treatment Settings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Bruise/Contusion1
  • Insufficient Information1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 28, 2025Measurement System Incompatibility; Measurement System Incompatibility

    IT WAS REPORTED THAT DURING KIT INSPECTION THE DEVICE DID NOT HOLD PRESSURE. DEVICE WAS SET TO 250MMHG; HOWEVER, THE DEVICE IS READING BETWEEN 230 TO 320MMHG. THERE WAS NO PATIENT INVOLVEMENT. DUE DILIGENCE IS COMPLETE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22916485 ↗
  • MalfunctionAug 12, 2025Measurement System Incompatibility; Measurement System Incompatibility

    IT WAS REPORTED THAT DURING AN UNKNOWN TIME, THE UNIT STRUGGLED TO MAINTAIN PRESSURE AND WAS CONSTANTLY MAKING THE INFLATING NOISE. IT WAS SET TO 250MMHG, INFLATE AND THE MACHINE WOULD HOVER BETWEEN 240-249MMHG BUT WITH A CONTINUOUS SOUND OF INFLATING. IT APPEARED TO BE WORKING HARD TO MAINTAIN THE PRESSURE. THERE WAS NO INFORMATION AVAILABLE REGARDING THE PATIENT IMPACT. DUE DILIGENCE IS COMPLETE; NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Insufficient Information

    MAUDE report 22782321 ↗
  • MalfunctionApr 4, 2024Measurement System Incompatibility; Measurement System Incompatibility

    IT WAS REPORTED THAT DURING SURGERY, THE PRESSURE ON THE DEVICE WAS NOT MAINTAINING THE PRESSURE IT WAS SET TO AT THE BEGINNING OF THE CASE. THERE WAS NO SURGICAL DELAY. DOCTORS WERE SEEING PATIENTS COMING BACK WITH SEVERE BRUISING FROM THE TOURNIQUET. THE PA STARTED NOTICING THAT THIS PROBLEM WAS ONLY OCCURRING WITH THIS SPECIFIC MACHINE. DUE DILIGENCE IS IN PROGRESS, NO FURTHER INFORMATION IS AVAILABLE.

    Patient problems: Bruise/Contusion

    MAUDE report 19045253 ↗
  • MalfunctionDec 4, 2023Use of Incorrect Control/Treatment Settings; Noise, Audible; Use of Incorrect Control/Treatment Settings; Noise, Audible

    IT WAS REPORTED THAT DURING SURGERY THE DEVICE WAS MAKING A PECULIAR NOISE AND THE PRESSURE SENSOR IS CONSTANTLY ACTIVE CALCULATING THE PRESSURE OCCURRING FROM BOTH PORTS. THERE WAS NO PATIENT IMPACT OR DELAY. DUE DILIGENCE IS IN PROCESS AND THERE IS NO ADDITIONAL INFORMATION AVAILABLE. THERE WAS NO ADVERSE EVENT ASSOCIATED WITH THE MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18255448 ↗
  • MalfunctionDec 19, 2022Deflation Problem; Deflation Problem

    IT WAS REPORTED DURING INSPECTION/TESTING, THE DEVICE SPONTANEOUSLY DEFLATED AND REQUIRED UNKNOWN REPAIRS. NO ADVERSE EVENT WAS REPORTED AS IT RELATES TO THE EVENT. DUE DILIGENCE IS COMPLETE AND NO ADDITIONAL INFORMATION IS AVAILABLE. IF ADDITIONAL INFORMATION IS PROVIDED, A SUPPLEMENTAL REPORT WILL BE SUBMITTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16010069 ↗
  • MalfunctionOct 27, 2022Output Problem; Output Problem

    IT WAS REPORTED THAT DURING PM, THE PRESSURE GIVEN OUT IS 10-13 MMHG MORE THAN WHAT IT WAS SET TO. THERE WAS NO PATIENT INVOLVEMENT. NO ADVERSE EVENTS WERE REPORTED AS A RESULT OF THIS MALFUNCTION. DUE DILIGENCE IS COMPLETE AND NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15682588 ↗

Other Tourniquet, Pneumatic devices

All Tourniquet, Pneumatic devices →