Skip to content

N/A 60-7070-156-00Recalls & reported problems

Zimmer Orthopaedic Surgical Products, Inc. · ZIMMER® STERILE DISPOSABLE TOURNIQUET CUFF WITH PROTECTIVE SLEEVE AND PLC, DUAL PORT, SINGLE BLADDER, 34 IN. (86 CM) · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00889024377202), received between Dec 13, 2022 and Jun 10, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Delivered as Unsterile Product” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 2 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Delivered as Unsterile Product2
  • Gas/Air Leak2

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Insufficient Information2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 10, 2025Delivered as Unsterile Product; Delivered as Unsterile Product

    IT WAS REPORTED THAT DURING THE ASSEMBLY OF TRAYS, THE DEVICE HAD A DEBRIS INSIDE THE SEALED STERILE PACKAGE. THERE WAS NO PATIENT HARM/INJURY OR SURGICAL DELAY AS THERE WAS NO PATIENT INVOLVEMENT. DUE DILIGENCE IS COMPLETED AND THERE IS NO ADDITIONAL INFORMATION AVAILABLE.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 22177160 ↗
  • MalfunctionJun 10, 2025Delivered as Unsterile Product; Delivered as Unsterile Product

    IT WAS REPORTED THAT DURING THE ASSEMBLY OF TRAYS, THE DEVICE HAD A DEBRIS INSIDE THE SEALED STERILE PACKAGE. THERE WAS NO PATIENT HARM/INJURY OR SURGICAL DELAY AS THERE WAS NO PATIENT INVOLVEMENT. DUE DILIGENCE IS COMPLETED AND THERE IS NO ADDITIONAL INFORMATION AVAILABLE.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 22177069 ↗
  • MalfunctionDec 22, 2022Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED THAT WHEN TURNING ON THE PRESSURE FOR THE ATS 4000, THE CUFF INFLATES AS NORMAL, BUT THE MACHINE NEEDS TO KEEP ADDING PRESSURE FOR THE ENTIRE PROCEDURE TO KEEP THE SUGGESTED PRESSURE FOR THIS PATIENT. THIS INDICATES THAT THERE IS A LEAK IN THE SINGLE USE CUFF. THE EVENT TIMING WAS DURING SURGERY. AN ALTERNATE DEVICE WAS AVAILABLE FOR USE. THERE WAS NO HARM OR DELAY REPORTED. NO ADVERSE EVENTS WERE REPORTED AS A RESULT OF THIS MALFUNCTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16034700 ↗
  • MalfunctionDec 13, 2022Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED THAT DURING SURGERY WHEN TURNING ON THE PRESSURE FOR THE ATS 4000 THE CUFF INFLATES AS NORMAL, BUT THE MACHINE NEEDS TO KEEP ADDING PRESSURE FOR THE ENTIRE PROCEDURE TO KEEP THE SUGGESTED PRESSURE FOR THIS PATIENT. THIS INDICATES THAT THERE IS A LEAK IN THE SINGLE USE CUFF. NO ADVERSE EVENTS WERE REPORTED AS A RESULT OF THIS MALFUNCTION. DUE DILIGENCE IS IN PROGRESS FOR THIS COMPLAINT; TO DATE NO ADDITIONAL INFORMATION OR PRODUCT HAS BEEN RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15968453 ↗

Other Tourniquet, Pneumatic devices

All Tourniquet, Pneumatic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page