CREO 5119.0542Recalls & reported problems

Globus Medical, Inc. · CREO Threaded 5.5 x 40mm Monoaxial Screw · Class 2

All models of CREO (100)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889095099300), received between Apr 17, 2026 and Apr 17, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Migration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Migration1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 17, 2026Migration

    IT WAS REPORTED THAT REVISION SURGERY FOR SCOLIOSIS WAS PERFORMED DUE TO THE FACT THAT, ON X-RAY IMAGING, ONE OF THE LOCKING ELEMENTS (SET SCREWS) APPEARED TO BE LOOSENED. DURING THE PROCEDURE, IT WAS DISCOVERED THAT A SECOND LOCKING ELEMENT WAS ALSO LOOSE, ALTHOUGH THIS HAD NOT BEEN VISIBLE ON THE PREOPERATIVE X-RAY. THE SCREW WAS REPLACED WITH ONE OF A LARGER DIAMETER, AND THE SET SCREWS WERE REPLACED WITH NEW ONES. THE ISSUE CONCERNS THE USE OF COBALT-CHROMIUM RODS. AS OBSERVED IN THE ATTACHED IMAGE, WHEN A TITANIUM ROD IS USED, THE SET SCREW CAN BE TIGHTENED DEEPLY AND SITS FLUSH WITH THE SCREW HEAD (TULIP). HOWEVER, WHEN A COBALT-CHROMIUM ROD IS USED, THE SET SCREW CANNOT BE TIGHTENED FURTHER AND REMAINS SLIGHTLY PROTRUDING ABOVE THE LEVEL OF THE SCREW HEAD.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24911448 ↗

Other Orthosis, spondylolisthesis spinal fixation devices

All Orthosis, spondylolisthesis spinal fixation devices →