Globus Medical, Inc. · Threaded Locking Cap Driver · Class 1

All models of CREO (100)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00889095173604), received between Sep 23, 2020 and Apr 7, 2026 — classified as 10 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 5 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Fracture2
  • Material Fragmentation2
  • Entrapment of Device1
  • Loose or Intermittent Connection1
  • Material Deformation1
  • Mechanical Problem1

Patient problems

  • Insufficient Information5
  • Failure of Implant2
  • Foreign Body In Patient2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 7, 2026Fracture

    IT WAS REPORTED THAT ON (B)(6) 2025, SURGERY WAS PERFORMED TO EXTEND THE FIXATION AREA FOR THE PATIENT WITH L5/S POSTERIORLY FIXED BY CREO DUE TO INFECTION. THE SURGEON TRIED TO REMOVE THE LOCKING CAP ON THE RIGHT S SUING A DRIVER, BUT IT WOULD NOT COME OFF. AS A RESULT, FOUR DRIVERS WERE USED, BUT ALL OF WHICH BROKE OFF. ONE OF THESE DRIVERS LEFT A BROKEN PIECE INSIDE THE LOCKING CAP. THE BROKEN PIECE COULD NOT BE REMOVED AND REMAINS IN THE LOCKING CAP. THE SURGEON INSERTED SCREWS INTO THE SAI AND CONNECTED THE RODS USING A COMPETITOR'S CONNECTOR.

    Patient problems: Foreign Body In Patient

    MAUDE report 24802193 ↗
  • MalfunctionMar 5, 2024Fracture; Fracture

    IT WAS N:MORTED THAT THE TIO OF THE THREADED LOCKINQ CAP DRIVER BROKE OFF WITHIN THE SET SCREW AND COULD NOT BE RETRIEVED.

    Patient problems: Failure of Implant

    MAUDE report 18839366 ↗
  • MalfunctionMar 5, 2024Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT DURING SURGERY THE DRIVER TIP BROKE WHILE SURGEON WAS IMPLANTING A LOCKING CAP AND IS RETAINED IN THE SCREW HEAD.

    Patient problems: Insufficient Information

    MAUDE report 18837435 ↗
  • MalfunctionMar 5, 2024Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT DURING SURGERY THE TIP OF THE CREO THREADED LOCKING CAP DRIVER WAS BROKEN AND LEFT IN A SET SCREW IN THE PATIENT.

    Patient problems: Insufficient Information

    MAUDE report 18834285 ↗
  • MalfunctionMar 4, 2024Material Fragmentation; Material Fragmentation

    THE TIP OF A THREADED LOCKING CAP DRIVER BROKE OFF IN THE LOCKING CAP DURING SURGERY. THE SURGEON WAS UNABLE TO REMOVE THE BROKEN TIP AND IT REMAINS IN THE PATIENT.

    Patient problems: Insufficient Information

    MAUDE report 18825399 ↗
  • MalfunctionMar 2, 2024Break; Break

    IT WAS REPORTED THE DISTAL TIP OF THE DRIVER BROKE OFF WHEN TRYING TO REMOVE THE SET SCREW. THE INSTRUMENT TIP WAS UNABLE TO BE RETRIEVED.

    Patient problems: Insufficient Information

    MAUDE report 18823390 ↗
  • MalfunctionFeb 29, 2024Material Deformation; Material Deformation

    IT WAS REPORTED THAT THE SURGEON USED THE CORRECT LOCKING CAP DRIVER TO IMPLANT THE CREO AMP THREADED END CAP. HE PASSED IT THROUGH THE COUNTER TORQUE, INTO THE 20MM REDUCTION TULIPS, AND BEGAN TIGHTENING THE END CAP INTO THE CONSTRUCT. UPON REMOVING THE DRIVER FROM THE INITIAL TIGHTENING HE NOTICED THE TIP OF THE SCREWDRIVER HAD BROKEN OFF IN THE END CAP. SURGEON ATTEMPTED TO REMOVE THE BROKEN PIECE, HOWEVER IT SAT FLUSH INSIDE THE END CAP. NO ADHESIVE OR INSTRUMENT WAS ABLE TO REMOVE IT AND THE BROKEN SCREWDRIVER TIP WAS LEFT WITHIN THE END CAP.

    Patient problems: Insufficient Information

    MAUDE report 18809726 ↗
  • MalfunctionJun 30, 2022Loose or Intermittent Connection

    IT WAS REPORTED THAT A CREO THREADED LOCKING CAP DRIVER TIP BROKE OFF IN THE LOCKING CAP AND REMAINS IN THE PATIENT.

    Patient problems: Failure of Implant

    MAUDE report 14873597 ↗
  • MalfunctionMay 10, 2021Break

    IT WAS REPORTED THAT THE TIP OF THE DRIVER BROKE OFF DURING PROVISIONAL TIGHTENING, AND REMAINS IN THE PATIENT.

    Patient problems: Foreign Body In Patient

    MAUDE report 11802232 ↗
  • MalfunctionSep 23, 2020Entrapment of Device

    IT WAS REPORTED THAT THE TIP OF THE THREADED LOCKING CAP DRIVER BROKE OFF IN THE SET SCREW. THE SCREW AND ROD WERE REMOVED AS A RESULT.