APEX 3D Total Ankle Replacement System P10-310-I210-SRecalls & reported problems
Paragon 28, Inc. · APEX 3D™ Cross-linked Vitamin E POLY, SIZE 2 x 10MM, NEUTRAL · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00889795072269), received between Jun 18, 2026 and Jun 18, 2026 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Exostosis (bone)1
- Joint Impingement1
- Osteopenia/ Osteoporosis1
- Pain1
- Scar Tissue1
- Swelling/ Edema1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 18, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT APPROXIMATELY 17 MONTHS POST IMPLANTATION OF A RIGHT TOTAL ANKLE ARTHROPLASTY, THE PATIENT PRESENTED WITH PAIN AND SWELLING AND UNDERWENT A REVISION WHERE SIGNIFICANT SCAR TISSUE WAS RESECTED FROM THE ANTERIOR JOINT, SIGNIFICANT OSTEOPHYTES WERE DEBRIDED FROM THE MEDIAL AND LATERAL GUTTERS, AND THE POLY WAS EXCHANGED. A COMPETITOR SCREW WAS PLACED TO HELP SUPPORT THE MEDIAL MALLEOLUS. DURING THE REVISION, IT WAS NOTED THAT THE TIBIAL AND TALAR COMPONENTS WERE WELL-FIXED. UPON EXAMINATION OF THE INTRAOPERATIVE X-RAYS, IT WAS NOTED THAT THE STRESS REACTION OF THE MEDIAL TIBIA WAS SUBSTANTIAL COMPARED TO PREOPERATIVE X-RAYS, AND IT WAS BELIEVED THAT THE MEDIAL PORTION OF THE TALUS AND THE MEDIAL PORTION OF THE TIBIA HAD SIGNIFICANT IMPINGEMENT AND THIS WAS CAUSING STRESS CHANGE OF THE DISTAL TIBIA. ATTEMPTS HAVE BEEN MADE AND ALL AVAILABLE INFORMATION HAS BEEN PROVIDED.
Patient problems: Exostosis (bone); Joint Impingement; Osteopenia/ Osteoporosis; Pain; Scar Tissue; Swelling/ Edema
MAUDE report 25548241 ↗
Other PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices
- Vantage 350-22-03Exactech, Inc. · Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer2 recalls2 reports
- Vantage 350-21-04Exactech, Inc. · Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer2 recalls0 reports
- INFINITY 33630023Wright Medical Technology, Inc. · PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER60 reports
- INFINITY 33600020Wright Medical Technology, Inc. · PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- Vantage 350-22-02Exactech, Inc. · Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer1 recall5 reports
- INFINITY 33650003Wright Medical Technology, Inc. · PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER55 reports
- INFINITY 33630022Wright Medical Technology, Inc. · PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER54 reports
- Vantage 350-21-02Exactech, Inc. · Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer1 recall4 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page