INFINITY ADAPTIS 33680004Recalls & reported problems

Wright Medical Technology, Inc. · Tibial Tray · Class 2 · Implant

All models of INFINITY ADAPTIS (8)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This is the Infinity Adaptis tibial tray, the metal base plate of a total ankle replacement made by Wright Medical Technology. The 30 reports mostly describe the implant not growing properly into the bone, so it loosens or sinks and patients need revision surgery, along with ongoing pain, cysts in the bone, and parts of the joint catching and impinging. 29 injuries and no deaths are reported. No recalls name this device. Reports in the last 12 months (4) are far fewer than the 13 in the prior 12 months.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
29
Deaths reported
0
Injuries reported
28
Recalls naming it
0

Summary

The FDA's MAUDE database contains 29 adverse event reports that list this exact device (DI 00889797069663), received between Dec 1, 2022 and Jun 8, 2026 — classified as 28 injuries, 1 malfunction.

The most frequently reported specific device problem is “Osseointegration Problem” (16 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 2 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 3 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 3 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 2 reportsAug 2025: 1 reportsSep 2025: 2 reportsOct 2025: 2 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Osseointegration Problem16
  • Adverse Event Without Identified Device or Use Problem7
  • Migration6
  • Insufficient Device Problem Information4
  • Break3
  • Fracture3
  • Implant subsidence3
  • Loss of Osseointegration3

Patient problems

  • Inadequate Osseointegration17
  • Pain8
  • Cyst(s)6
  • Implant Pain5
  • Insufficient Information4
  • Failure of Implant3
  • Joint Impingement3
  • Inflammation2

Recent adverse event reports

The 25 most recent of 29 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 8, 2026Loss of Osseointegration

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE ANKLE JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED FOR THE MONTHLY REPORT OF MAY 2026. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT A PATIENT REQUIRED REVISION SURGERY DUE TO ASEPTIC LOOSENING OF TIBIAL COMPONENT WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Osteolysis

    MAUDE report 25426886 ↗
  • InjuryMay 1, 2026Insufficient Device Problem Information

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY FOR REASONS THAT ARE NOT AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Insufficient Information

    MAUDE report 25057141 ↗
  • InjuryJan 27, 2026Loss of Osseointegration; Osseointegration Problem

    THE STRYKER PROPHECY TEAM HAS RECEIVED A CT SCAN FOR UPCOMING REVISION SURGERY DUE TO PROGRESSIVE ANTERIOR TIBIAL SUBSIDENCE AS WELL AS POSTERIOR TALAR LUCENCY CONSISTENT WITH SUBCHONDRAL CYST FORMATION DUE TO ABNORMAL ANKLE JOINT MECHANICS/PRESSURES.

    Patient problems: Cyst(s); Inadequate Osseointegration

    MAUDE report 24194246 ↗
  • InjuryOct 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SUBJECT: (B)(6). INFINITY WITH ADAPTIS ANKLE (ITAR-2) STUDY. ANKLE IMPINGEMENT SYNDROME. PERSISTENT PAIN. PHYSICIANS NOTE DOCUMENTS LIMITED DORSIFLEXION AND ANTERIOR IMPINGEMENT PAIN. PLAN FOR ARTHROSCOPIC DEBRIDEMENT ANTERIORLY TO HELP WITH PAIN AND MAY IMPROVE MOTION ALSO. OPERATION PERFORMED (B)(6) 2021: PATIENT UNDERWENT REOPERATION FOR RIGHT ANKLE ARTHROSCOPIC DEBRIDEMENT. AE UPDATE 11-JAN-2022: PATIENT REPORTS ARE IMPROVING. DIRECTED TO WEIGHT BEAR AS TOLERATED AND AGGRESSIVE PHYSICAL THERAPY WORKING ON RANGE OF MOTION RECOMMENDED.

    Patient problems: Joint Impingement; Pain

    MAUDE report 23402215 ↗
  • InjuryOct 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SUBJECT: (B)(6). STUDY: STRYKER ITAR-2 - INFINITY WITH ADAPTIS. GUTTER IMPINGEMENT: NARRATIVE OF ADVERSE EVENT : PATIENT PRESENTED WITH CONTINUED PAIN IN HIS MEDIAL ANKLE. EXAM OF ANKLE FOUND SLIGHT ANKLE VARUS, TENDERNESS PALPATION OVER THE MEDIAL GUTTER, ESPECIALLY DISTALLY. ISOLATED RIGHT ANKLE MEDIAL GUTTER DEBRIEDMENT PERFORMED.

    Patient problems: Joint Impingement; Pain

    MAUDE report 23402204 ↗
  • InjurySep 17, 2025Osseointegration Problem; Implant subsidence; Osseointegration Problem; Implant subsidence

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT REVISION SURGERY MAY BE REQUIRED. A TOTAL ANKLE REPLACEMENT WITH A WRIGHT MEDICAL/STRYKER DEVICE WAS PREVIOUSLY PERFORMED FOR ARTHRITIS AND ANKLE PAIN. REPORTS INCLUDE SWELLING AND MEDIAL ANKLE PAIN, WITH IMAGING SUGGESTING A POSSIBLE MEDIAL MALLEOLUS STRESS FRACTURE AND POTENTIAL TIBIAL TRAY LOOSENING. NO REVISION HAS BEEN PERFORMED TO DATE. BONE QUALITY WAS DESCRIBED AS GOOD, AND COMPLIANCE WITH MOBILIZATION INSTRUCTIONS WAS NOTED, THOUGH A PHYSICALLY ACTIVE LIFESTYLE MAY HAVE CONTRIBUTED TO THE REPORTED SYMPTOMS.

    Patient problems: Cyst(s); Inadequate Osseointegration; Pain; Swelling/ Edema

    MAUDE report 23074454 ↗
  • InjurySep 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SUBJECT: (B)(4). STUDY: STRYKER ITAR-2 - INFINITY WITH ADAPTIS. TALAR COMPONENT IMPINGEMENT AND CONTINUED PAIN. SUBJECT CONTINUES TO HAVE SUSTAINED ANTERIOR MEDIA ANKLE AND DISTAL TIBIAL PAIN. PAIN IS LIKELY DUE TO IMPINGEMENT BETWEEN HIS MEDIAL MALLEOLUS AND TALAR COMPONENT, LIKELY RELATED TO HIS MILD VARUS ALIGNMENT.

    Patient problems: Implant Pain; Joint Impingement

    MAUDE report 22961234 ↗
  • InjuryAug 20, 2025Loss of Osseointegration; Insufficient Device Problem Information; Migration; Loss of Osseointegration; Insufficient Device Problem Information; Migration

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY DUE TO IMPLANT FAILURE.

    Patient problems: Cyst(s); Inadequate Osseointegration; Insufficient Information

    MAUDE report 22853875 ↗
  • InjuryJul 18, 2025Osseointegration Problem; Migration; Osseointegration Problem; Migration

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT HAS PAIN AT THE ANKLE JOINT MAY REQUIRE A REVISION SURGERY OF BOTH THE TIBIAL AND TALAR COMPONENTS. IT LOOKS LIKE THE PRIMARY TIBIAL CUT WAS OFF AXIS AND THE ANKLE IS IN VARUS AND THE PHYSICIAN IS TRYING TO DETERMINE IF THE PATIENT NEEDS A TIBIA OSTEOTOMY AND LEAVE THE ANKLE OR IGNORE THE TIBIA AND REVISE THE TIBIA SO IT¿S NOT IN VARUS.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 22547056 ↗
  • InjuryJul 2, 2025Osseointegration Problem; Implant subsidence; Osseointegration Problem; Implant subsidence

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY BECAUSE THE TIBIAL COMPONENT IS LOOSE AND THERE IS ANTERIOR SUBSIDENCE. THE PATIENT IS ALSO COMPLAINING OF PAIN. THE TALAR IMPLANT WILL BE REVISED TO MATCH THE TIBIAL INBONE COMPONENT.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 22383466 ↗
  • InjuryJun 17, 2025Osseointegration Problem; Osseointegration Problem

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY DUE TO TIBIAL COMPONENT LOOSENING AND CLINICAL PAIN. THE SURGEON PLANS TO REVISE BOTH THE TIBIA AND TALUS.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 22231191 ↗
  • InjuryMay 20, 2025Osseointegration Problem; Insufficient Device Problem Information; Implant subsidence; Osseointegration Problem; Insufficient Device Problem Information; Implant subsidence

    THE STRYKER PROPHECY TEAM HAS RECEIVED A CT SCAN FOR THE UPCOMING REVISION SURGERY. IT WAS ALSO REPORTED THAT THERE WAS: "SINTERING OF THE TIBIAL COMPONENT WITH TILTING, INTERNAL MALLEOLUS FRACTURE."

    Patient problems: Bone Fracture(s); Inadequate Osseointegration

    MAUDE report 22053983 ↗
  • InjuryFeb 26, 2025Osseointegration Problem; Osseointegration Problem

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY OF TIBIAL COMPONENT FOR REASON OF LOOSENING OF TIBIA AND ONGOING PAIN .

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 21475139 ↗
  • InjuryFeb 26, 2025Osseointegration Problem; Migration; Osseointegration Problem; Migration

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY OF TIBIAL COMPONENT FOR REASONS OF LOOSE TIBIAL TRAY AND ASEPTIC LOOSENING OF THE TIBIA WITH ONGOING PAIN.

    Patient problems: Inadequate Osseointegration; Pain

    MAUDE report 21471115 ↗
  • InjuryFeb 26, 2025Osseointegration Problem; Osseointegration Problem

    AS REPORTED: "SUBJECT: (B)(6). INFINITY¿ WITH ADAPTIS¿ TOTAL ANKLE REPLACEMENT FOLLOW-UP (ITAR2). ASEPTIC LOOSENING: SUBJECT REPORTED GRADUAL WORSENING PAIN IN THE STUDY ANKLE. [THE SURGEON'S] PA NOTED THAT THE PAIN SEEMED "SOMEWHAT MIGRATORY AROUND THE ANTERIOR ANKLE, MEDIAL AND LATERAL HINDFOOT EVEN UP INTO THE LOWER LEG WITH SOME TENDERNESS MEDIALLY ALONG TIBIA." PA DID NOT NOTE ANY SUBSIDENCE OF HARDWARE ON X-RAYS. SUBJECT RECEIVED FLUOROSCOPIC GUIDED RIGHT SUBTALAR JOINT INJECTION AS TREATMENT. (B)(6) 2023: WORSENING. LOOSENING OF TIBIAL COMPONENT NOTED ON X-RAYS. (B)(6) 2023: NO CHANGE. NO PROGRESSION OF LOOSENING. PI ATTRIBUTED ANKLE PAIN TO LOOSENING AT THIS VISIT. (B)(6) 2024: PAIN WAS RESOLVED AND X-RAYS SHOWED NO FURTHER PROGRESSION. RESOLVED WITHOUT SEQUELAE."

    Patient problems: Implant Pain; Inadequate Osseointegration

    MAUDE report 21468381 ↗
  • InjuryNov 13, 2024Osseointegration Problem; Migration; Osseointegration Problem; Migration

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY DUE TO TIBIAL COMPONENT LOOSENING.

    Patient problems: Cyst(s); Inadequate Osseointegration

    MAUDE report 20679624 ↗
  • InjuryOct 11, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "SUBJECT: (B)(6) INFINITY¿ WITH ADAPTIS¿ TOTAL ANKLE REPLACEMENT FOLLOW-UP (ITAR2). (B)(6) 2022: WOUND DEHISCENCE. DELAYED WOUND HEALING. SMALL AREA OF WOUND DEHISCENCE NOTED IN THE FLAP AREA OF THE INCISION AT THE 3 WEEK POST OP VISIT. RECOMMENDATIONS INCLUDED XEROFORM DRY DRESSING CHANGES DAILY, WASH WITH SOAP AND WATER, CONTINUE NONWEIGHT BEARING, AND FOLLOW-UP IN 1 WEEK. (B)(6) 2022: IMPROVING. INCISION IS HEALING WELL. 1 SMALL AREA OF ESCHAR. FOLLOW-UP 2-3 WEEKS. (B)(6) 2022: WORSENING. REDNESS AROUND INCISION SITE WITH NEW DRAINAGE. RECOMMEND IRRIGATION AND DEBRIDEMENT WITH IV ANTIBIOTICS AND REVISION WITH POLY EXCHANGE. EVERLAST POLY WAS REMOVED AND DISCARDED. (B)(6) 2022: IMPROVING. (B)(6) 2022: IMPROVING. INCISION HEALING WELL. MEDIHONEY AND GAUZE DRESSING. DAILY DRESSING CHANGES. OKAY TO WASH WITH SOAP AND WATER. NONWEIGHT BEARING. HOME PT, VERY GENTLE ANKLE RANGE OF MOTION. (B)(6) 2022: IMPROVING. INCISION HEALING WELL. INCISION HAS ALMOST FULLY HEALED, JUST 1 PINPOINT AREA THAT HE CAN CONTINUE MEDIHONEY AND GAUZE IN THE NEXT FEW DAYS UNTIL THIS HEALS UP. GRADUAL PROGRESSION TO FULL WEIGHTBEARING IN THE TALL BOOT. COMMENCE PHYSICAL THERAPY. (B)(6) 2022: IMPR

    Patient problems: Inflammation; Wound Dehiscence

    MAUDE report 20426141 ↗
  • InjuryOct 11, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "SUBJECT: (B)(6) INFINITY¿ WITH ADAPTIS¿ TOTAL ANKLE REPLACEMENT FOLLOW-UP (ITAR2). (B)(6) 2022: DORSAL FOOT NEURITIS. PERSISTENT NERVE PAIN. NERVE TINGLING & NUMBNESS-DORSAL FOOT. (B)(6) 2023: IMPROVING. HEALING AND PROGRESSING WELL. TREATMENT UPDATED TO INCLUDE ORTHOTICS. (B)(6) 2023: ORTHOTICS, ULTRASOUND GUIDED INJECTION. (B)(6) 2023: IMPROVING. SIGNIFICANT RELIEF AFTER ULTRASOUND INJECTION."

    Patient problems: Implant Pain; Numbness

    MAUDE report 20426094 ↗
  • InjuryOct 1, 2024Osseointegration Problem; Osseointegration Problem

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY OF BOTH THE TIBIAL AND TALAR COMPONENTS DUE TO SUBSIDENCE.

    Patient problems: Inadequate Osseointegration; Limb Fracture

    MAUDE report 20344523 ↗
  • InjuryJul 18, 2024Osseointegration Problem; Osseointegration Problem

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY DUE TO LOOSE TIBIAL COMPONENT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 19777607 ↗
  • InjuryJun 26, 2024Osseointegration Problem; Osseointegration Problem

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY DUE TO IMPLANT LOOSENING.

    Patient problems: Inadequate Osseointegration

    MAUDE report 19620748 ↗
  • InjuryJun 24, 2024Osseointegration Problem; Migration; Osseointegration Problem; Migration

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY OF BOTH THE TIBIAL AND TALAR COMPONENTS DUE TO LOOSENING OF THE TIBIAL COMPONENT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 19601676 ↗
  • InjuryMay 7, 2024Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PATIENT MAY REQUIRE A REVISION SURGERY FOR REASONS THAT ARE NOT AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Cyst(s); Insufficient Information

    MAUDE report 19262571 ↗
  • InjuryNov 7, 2023Osseointegration Problem; Osseointegration Problem

    THE DIGITAL STRYKER PROPHECY TEAM RECEIVED A CT SCAN INDICATING THAT THE PHYSICIAN NOTED THAT TIBIAL COMPONENT WILL HAVE TO BE REVISED DUE TO BEING LOOSE AND IN VARUS. IT WAS REPORTED THAT THE PATIENT PRESENTED WITH PAIN AND COLLAPSED. THE PATIENT MAY REQUIRE A REVISION SURGERY FOR REASONS THAT ARE NOT AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Implant Pain; Inadequate Osseointegration

    MAUDE report 18088284 ↗
  • InjuryAug 22, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT PRESENTED 6 WEEKS POST PROCEDURE WITH MRSA INFECTION. THE PHYSICIAN EXPLANTED ALL IMPLANTS AND IMPLANTED A CEMENT SPACER.

    Patient problems: Bacterial Infection; Fluid Discharge; Wound Dehiscence

    MAUDE report 17599446 ↗

Other PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices

All PROSTHESIS, ANKLE, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices →