FREEDOM SOLO ART23SGRecalls & reported problems
Corcym Canada Corp · Class 3 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00896208000382), received between May 19, 2017 and May 19, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Inadequacy of Device Shape and/or Size” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Inadequacy of Device Shape and/or Size1
- Insufficient Device Problem Information1
Patient problems
- Aortic Insufficiency1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 19, 2017Inadequacy of Device Shape and/or Size; Insufficient Device Problem Information; Inadequacy of Device Shape and/or Size; Insufficient Device Problem Information
DURING SURGERY ON (B)(6) 2017, IT WAS NOTICED THAT THE COMMISSURE BETWEEN RIGHT AND NON-CORONARY CUSPS WERE NOT AT THE SAME HEIGHT, HOWEVER, ALL COMMISSURES HOWEVER WERE AT SAME DISTANCE FROM EACH OTHER. THE SURGEON DECIDED TO IMPLANT SOLO 23MM VALVE AND AFTER DECLAMPING THE AORTA, A CENTRAL LEAK 2/4 WAS NOTICED ON ECHOCARDIOGRAM. THEREFORE THE VALVE WAS EXPLANTED AND A PERIMOUNT SIZE 21 VALVE WAS IMPLANTED. THE DELAY IN SURGERY WAS ABOUT 60 MINUTES. THE PATIENT IS DOING WELL NOW AND HAS RETURNED HOME.
Patient problems: Aortic Insufficiency
MAUDE report 6578114 ↗
Other heart-valve, non-allograft tissue devices
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue2 deaths404 reports
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue385 reports
- PERCEVAL PVS23Corcym Canada Corp · heart-valve, non-allograft tissue26 deaths337 reports
- MOSAIC® 305C23Medtronic, Inc. · heart-valve, non-allograft tissue327 reports
- MOSAIC® 305C25Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths324 reports
- FREESTYLE® FR995-27Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths318 reports
- FREESTYLE® FR995-29Medtronic, Inc. · heart-valve, non-allograft tissue288 reports
- FREESTYLE® FR99525Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths280 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page