Skip to content

Tandem 126654Recalls & reported problems

Smith & Nephew, Inc. · TANDEM UNIPOLAR HEAD 54MM · Class 2 · Implant

All models of TANDEM (58)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010079831), received between Dec 15, 2021 and Dec 15, 2021 — classified as 1 injury.

1 other recall cover devices cleared under the same FDA submission (K211176, K231448, K896580); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Unspecified Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 15, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, AFTER A THR SURGERY PERFORMED ON ((B)(6) 2021), DUE TO INFECTION A TWO STAGES REVISION SURGERY WAS PERFORMED. ON THE FIRST STAGE THE TANDEM UNIPOLAR HEAD 54MM (CASE (B)(4)), THE TANDEM UNIPOLAR 12/14 TAPER SLEEVE + 0 (CASE (B)(4)) AND THE SPECTRON EF 12/14 TAPER LONG STRAIGHT 225MM SMALL (CASE (B)(4)) WERE EXPLANTED AND A REVISION LONG STEM SPECTRON WITH A TANDEM UNIPOLAR HEAD, COATED IN ANTIBIOTIC CEMENT WERE PLACED INTO THE PATIENT. THE SECOND STAGE REVISION SURGERY WAS PERFORMED ON (B)(6) 2021 TO EXTRACT THE DEVICES THAT WERE PUT IN ON THE FIRST STAGE SURGERY AND TO EXCHANGE THEM WITH THE IMPLANTS. CURRENT HEALTH STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Unspecified Infection

    MAUDE report 13012873 ↗

FDA clearance and classification

Cleared through 510(k) K231448 on Jul 19, 2023 (decision: Substantially Equivalent). Submitted by Smith & Nephew, Inc. as “TANDEM Hip System”. The FDA review took 62 days. FDA record ↗

Cleared through 510(k) K211176 on Jul 1, 2022 (decision: Substantially Equivalent). Submitted by Smith & Nephew, Inc. as “Smith & Nephew Hip Systems”. The FDA review took 437 days. FDA record ↗

Cleared through 510(k) K896580 on Feb 15, 1990 (decision: Substantially Equivalent). Submitted by Richards Medical Co., Inc. as “Uni-Polar Head”. The FDA review took 90 days. FDA record ↗

The FDA regulates product code LZY (prosthesis, hip, hemi-, femoral, metal ball) under 21 CFR 888.3360 as a Class II device. 21 CFR 888.3360 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K211176, K231448, K896580. One submission often covers many models, so check the product and lot details in each record.

  • Z-0326-2025 · Oct 15, 2024 · Open, Classified
    Tandem Intl Bipolar Cocr Shell/UHMWPE Liner, TI-6AL-4V Retaining Ring, 28MM I.D. 46 MM O.D., REF 71324046, sterile, femoral head bipolar component of the Tandem Bipolar Hip System.

Common questions about the Tandem 126654

Has the Tandem 126654 been recalled?

No FDA recall record in our data names this exact device identifier (DI 03596010079831), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the Tandem 126654?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Dec 15, 2021. That report lists patient problem “Unspecified Infection” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Tandem 126654?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Tandem 126654 FDA approved?

It was cleared through 510(k) K896580 on Feb 15, 1990; its record lists 3 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the Tandem 126654 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the Tandem 126654, and is it still sold?

The FDA's device database lists Smith & Nephew, Inc. as the company responsible for it (brand Tandem, model 126654). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Prosthesis, hip, hemi-, femoral, metal ball devices

All Prosthesis, hip, hemi-, femoral, metal ball devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page