GENESIS II 71430574Recalls & reported problems
Smith & Nephew, Inc. · GENESIS II RESURFACING PATELLA TRIAL 29MM · Class 1
All models of GENESIS II (462)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010212214), received between Apr 11, 2021 and Nov 23, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break2
- Crack1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 23, 2021Break; Crack; Break; Crack
IT WAS REPORTED THAT, THE LISTED DEVICES WERE CRACKED AND OR BROKEN. AS THIS WAS NOTICED UPON FIELD INSPECTION, THERE WAS NOT PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12861545 ↗MalfunctionApr 11, 2021Break; Break
((B)(4)) IT WAS REPORTED THAT DURING TKA SURGERY, THE GENESIS II RESURFACING PATELLA TRIAL 26MM BROKE OUTSIDE THE PATIENT. THE PROCEDURE WAS FINISHED USING THE SAME DEVICE, WITHOUT SURGICAL DELAY AND NO INJURY TO THE PATIENT. ((B)(4)) IT WAS REPORTED THAT DURING TKA SURGERY, THE GENESIS II RESURFACING PATELLA TRIAL 29MM BROKE OUTSIDE THE PATIENT. THE PROCEDURE WAS FINISHED USING THE SAME DEVICE, WITHOUT SURGICAL DELAY AND NO INJURY TO THE PATIENT. ((B)(4)) IT WAS REPORTED THAT DURING TKA SURGERY, THE GENESIS II RESURFACING PATELLA TRIAL 32MM BROKE OUTSIDE THE PATIENT. THE PROCEDURE WAS FINISHED USING THE SAME DEVICE, WITHOUT SURGICAL DELAY AND NO INJURY TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11646712 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page