SOFTSILK 7207005Recalls & reported problems
Smith & Nephew, Inc. · 8 X 25 MM SOFTSILK SCREW 1.5 STERILE · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03596010252661), received between Dec 7, 2020 and Dec 7, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Expulsion” (1 report).
1 other recall cover devices cleared under the same FDA submission (K921481); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Expulsion1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 7, 2020Expulsion; Expulsion
IT WAS REPORTED THAT THE DURING KNEE SURGERY, THE SCREW WAS FOUND SLIPPED FROM THE BONE AND COULD NOT BE IMPLANTED-IN. THE SCREW WAS RETRIEVED FROM PATIENT BY TWEEZERS. A BACKUP DEVICE WAS AVAILABLE TO COMPLETE THE PROCEDURE AND NO SIGNIFICANT DELAY OR OTHER COMPLICATIONS REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: Insufficient Information
MAUDE report 10957826 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K921481. One submission often covers many models, so check the product and lot details in each record.
- Z-1510-2021 · Apr 8, 2021 · TerminatedCANNU-Flex SILK Interference Screws 6 mmx 30 mm - Product Usage: used for interference fixation of bone-tendon-bone of soft tissue grafts in anterior cruciate ligament reconstructi
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page